期刊文献+

乙苯脱氢单元后系统苯乙烯聚合的原因及解决方法 被引量:2

The Reason and Solution of Undesirable Styrene Polymerization in Final Section of Ethylbenzene Dehydrogenation Unit
下载PDF
导出
摘要 由于苯乙烯装置乙苯脱氢单元苯乙烯单体浓度升高,导致该单元后系统冷却器和尾气压缩机中聚合物含量明显增加。为了有效控制苯乙烯聚合的发生,采取了添加阻聚剂,通过调节阻聚剂注入泵冲程的方式优化注入量,用乙苯冲洗脱氢单元后系统冷却器进料口的措施。优化措施实施后,脱氢反应物中苯乙烯的浓度提高了0.85%,压缩机透平蒸汽用量由14 t/h降低到12 t/h,降低了装置的生产成本。 As concentration of styrene monomers was excessive in the ethylbenzene dehydrogenation unit of styrene plant resulted in sharp rise of the polymers content in the after-cooler and exhaust compressor.In order to control availably polymerization of the styrene following measures,inhibitor applied,stroke way of injection pump for the inhibitor adjusted to optimize the use level,and feed inlet of the after-cooler washed with ethylbenzene,were implemented.Because of the measures put into effect,the styrene concentration in dehydrogenation reactant was increased by 0.85%,the steam consumption for compressor turbine declined from 14 t/h to 12 t/h.
作者 王晓艳
出处 《石化技术》 CAS 2012年第1期31-34,共4页 Petrochemical Industry Technology
关键词 苯乙烯 脱氢反应 阻聚剂 styrene dehydrogenation reaction inhibitor
  • 相关文献

参考文献2

二级参考文献1

  • 1张自义,郑大刚,邵云,魏秀英.乙烯基单体自由基聚合阻聚反应——Ⅵ.2,2,6,6-四甲基-4-羟基哌啶氧自由基对苯乙烯聚合的阻聚效应[J]合成橡胶工业,1987(04).