摘要
论述了低压旋膜除氧器除氧塔头由于在设计和安装中存在的缺陷,导致除氧不合格,通过对原因的查找,并采取技术改造对缺陷进行处理,取得了较好的效果。
The problems in design and installation of the deoxygenizing tower head of DCM-150 low pressure rotating film deaerator are presented.The problems cause unqualified deoxidizing effect.The causes are found out and the problems are solved by means of technical measures.Good results have been achieved.
出处
《冶金动力》
2012年第5期45-47,共3页
Metallurgical Power
关键词
低压旋膜除氧器
除氧塔头
除氧
加热
技术改造
low pressure rotating film deaerator
deoxygenizing tower head
deoxygenization
heating
technical reconstruction