摘要 Objective To test a modified otologic drill under different drilling conditions for its ability to identify drilling faults and stop drilling.Methods Based on force analysis and previous works,an otologic drill was modified and equipped with three sensors.Under various conditions,the drill was used to simulate three drilling faults and normal drilling,and signals from the drill were analyzed to extract the characteristic signal.A multi-sensor information fusion system and a stop program were designed to recognize drilling faults and stop drilling.Results Signals from each sensor changed consistently in response to drilling condition changes,with high repeatability and regularity.The average identification rate was 72.625%,68.575%,70.5% and 81.3% respectively for the three simulated drilling faults and normal drilling.The stop program stopped drilling in 0.2~ 0.3 seconds when a drilling faults was detected.Conclusions This study shows that the forces acting on the drill bit change predictably in the three simulated drilling conditions;that using suitable BP neural networks,the drilling faults can be reliably identified,and that a stop program based upon characteristic signal recognition can stop drilling quickly upon detecting drilling faults.This lays a foundation for development of a system capable of predicting drilling faults and automatic drill control.Further studies are being undertaken for practical application of such a system. Objective To test a modified otologic drill under different drilling conditions for its ability to identify drilling faults and stop drilling.Methods Based on force analysis and previous works,an otologic drill was modified and equipped with three sensors.Under various conditions,the drill was used to simulate three drilling faults and normal drilling,and signals from the drill were analyzed to extract the characteristic signal.A multi-sensor information fusion system and a stop program were designed to recognize drilling faults and stop drilling.Results Signals from each sensor changed consistently in response to drilling condition changes,with high repeatability and regularity.The average identification rate was 72.625%,68.575%,70.5% and 81.3% respectively for the three simulated drilling faults and normal drilling.The stop program stopped drilling in 0.2~ 0.3 seconds when a drilling faults was detected.Conclusions This study shows that the forces acting on the drill bit change predictably in the three simulated drilling conditions;that using suitable BP neural networks,the drilling faults can be reliably identified,and that a stop program based upon characteristic signal recognition can stop drilling quickly upon detecting drilling faults.This lays a foundation for development of a system capable of predicting drilling faults and automatic drill control.Further studies are being undertaken for practical application of such a system.
出处 《Journal of Otology》 2010年第2期104-110,共7页 中华耳科学杂志(英文版)
基金 supported by Beijing Municipal Natural Science Foundation(4092027)
关键词 DRILL otologic surgery FORCE SENSOR back propagation(BP) neural network drill otologic surgery force sensor back propagation(BP) neural network
  • 相关文献

参考文献10

  • 1Wormald PJ,Nilssen EL.Do the complications of mas- toid surgery differ from those of the disease?[].Clin Oto- laryngol Allied Sci.1997
  • 2Strauss G,Koulechov K,Hofer M,Dittrich E,Grunert R,Moeckel H,Muller E,Korb W,Trantakis C,Schulz T,Meixensberger J,Dietz A,Lueth T.The Navigation - Controlled Drill in Temporal Bone Surgery: A Feasibility Study[].Laryngoscope.2007
  • 3Majdani O,Bartling SH,Leinung M,Stver T,Lenarz M,Dullin C,Lenarz T.A true minimally invasive ap- proach for cochlear implantation: high accuracy in cra- nial base navigation through flat-panel-based volume computed tomography[].Otology and Neurotology.2008
  • 4Federspil PA,Geisthoff UW,Henrich D,Plinkert PK.Development of the first force-controlled robot for o- toneurosurgery[].Laryngoscope.2003
  • 5Brett PN,Taylor RP,Proops D,Coulson C,Reid A,Griffiths MV.A surgical robot for cochleostomy[].Pro- ceedings of the th Annual International Conference of the IEEE EMBS.2007
  • 6Coulson CJ,Reid AP,Proops DW,Brett PN.ENT challenges at the small scale[].Int J Med Robotics Comput Assist Surg.2007
  • 7Coulson CJ,Taylor RP,Reid AP,Griffiths MV,Proops DW,Brett PN.An autonomous surgical robot for drilling a cochleostomy: preliminary porcine trial[].Clinical Otolaryngology.2008
  • 8Shen P,Feng G,Cao T,Gao Z,Li X.Automatic identi-fication of otologic drilling faults: a preliminary report[].Int J Med Robot.2009
  • 9Cao T,Li X,Gao Z,Feng G,Shen P.Automatic identi- fication of otological drilling faults: an intelligent recognition algorithm[].Int J Med Robot.2010
  • 10Manikya Kanti K,Srinivasa Rao P.Prediction of bead geometry in pulsed GMA welding using back propa- gation neural network[].Journal of Materials.2008