摘要
基于温排水物理模型相似关键条件,建立了澳门路环发电厂温排水物理模型。详细研究了澳门机场扩建及机场以西水域规划方案实施后电厂温排水对周边水体的影响。通过改变不同排水口位置,对排水口附近水域表面温升以及取水口的取水温升分布进行对比分析,推荐了最优的工程布置方案,明确了推荐方案在各种典型潮位下的温升影响。对同类工程有参考意义。
Based on the key similarity condition of physical model of thermal effluent,the thermal effluent physical model of Luhan Power Plant in Macao is established.After the expanding of Macao International Airport and implement of the planning schemes in the water area in the west of the airport,the topography around the area will be changed and the influence of thermal effluent of the plant on the water body around is studied in detail.Through changing the locations of the outfalls,the distribution of temperature rise of the water in the surface of water intake area and the outfall are compared and analyzed.The optimal project arrangement scheme was recommended.The influence of temperature rising under each designed tidal level was made clear for the recommended project case.
出处
《人民长江》
北大核心
2012年第20期62-65,共4页
Yangtze River
关键词
温水排放
物理模型
取排水口
路环电厂
thermal effluent
physical model
water intake and outfall
Luhuan power plant