摘要
对马鞍山当涂发电有限公司汽动给水泵交流润滑油泵实际运行中存在的问题、改造方法进行叙述,提出发电厂低压辅机电气联锁回路设计的新思路,并获得改造效果,运行情况良好;可对存在相似问题的低压辅机电气联锁回路改造提供参考。
The paper describes the existing problems and transformation methods of AC lubrication oil pump practical operation in DangTu Ma Anshan power company limited,puts forward a low voltage auxiliary electric power new idea of interlocking circuit design,get information effect and run in good condition,and also provide the reference for similar problems existing within the industry for low voltage auxiliary electrical interlocking circuit transformation.
出处
《安徽电力》
2012年第4期35-37,共3页
Anhui Electric Power
关键词
发电厂
汽动给水泵
交流润滑油泵
电气联锁
回路改造
power plant
steam feed pump
AC lubricating oil pump
electrical interlocking