期刊文献+

某300MW机组锅炉排烟温度偏高原因分析及治理 被引量:20

High exhaust temperature of a 300 MW unit boiler:reason analysis and countermeasures
下载PDF
导出
摘要 对某电厂300MW机组锅炉排烟温度异常偏高的原因进行了分析,认为其主要因燃气脉冲吹灰器吹灰效果不佳导致尾部受热面积灰严重,使水平低温过热器和省煤器吸热量减少所致。通过采取减小干渣机漏风、调整燃烧器摆角以及将燃气脉冲吹灰器改造为蒸汽吹灰器等措施,使排烟温度下降了16℃,锅炉效率提高了0.94百分点,供电煤耗约降低3.29g/(kW.h),提高了机组运行的安全性和经济性。 The exhaust temperature of a 300 MW unit boiler was higher than the designed value.To enhance the security and economy of the unit operation,reason analysis was conducted.Decrease in heat absorption of horizontal low-temperature reheater and economizer was considered as the major factor,which resulted from serious ash deposition on final heating surfacing caused by poor soot blowing effect of the flue gas impulse soot blower.Thus,several measures were carried out,such as reducing the air leakage in dry residue machine,adjusting the burner injection angle,and transforming the flue gas impulse soot blower into steam soot blower.After improvement,the exhaust temperature dropped by 16 ℃,the boiler efficiency increased by 0.94%,and the coal consumption decreased by about 3.29 g/(kW·h).The safety and economy of the unit was significantly enhanced.
出处 《热力发电》 CAS 北大核心 2013年第2期110-113,94,共5页 Thermal Power Generation
关键词 300 MW机组 锅炉 排烟温度 受热面 积灰 吹灰器 锅炉效率 300 MW unit boiler exhaust temperature heating surface ash deposition soot blower boiler efficiency
  • 相关文献

参考文献6

二级参考文献14

  • 1周新刚,刘志超,路春美.燃烧调整降低锅炉NO_x排放的试验研究[J].电站系统工程,2005,21(5):16-18. 被引量:23
  • 2胡秀莲.中国电力生产及环境问题[J].中国能源,2005,27(11):11-17. 被引量:17
  • 3冯宝安.锅炉煤质特性和混煤燃烧的应用研究[M].南京:东南大学出版社,1997.
  • 4徐国璋,等.中国电力百科全书[M].北京:中国电力出版社,1995.
  • 5刘志超,等.大型锅炉低NOx燃烧技术试验研究[R].山东电力研究院,2003.
  • 6A M Li, X D Li, S Q Li, et al. Experimental studies on municipal solid waste pyrolysis in a laboratory - scale rotary kiln[J]. Energy, 1994,24 : 209 - 218.
  • 7王春昌.入炉风量与炉膛出口烟气温度的相关性研究[J].热力发电,2007,36(7):37-39. 被引量:9
  • 8朱宝田,杨寿敏.超临界参数应用于350Mw级机组的可行性研究[A].中国动力工程学会透平专业委员会2007年学术研讨会论文集[C].2007.
  • 9孟勇,王国忠,等.瑞金电厂1号(2号)锅炉性能考核试验报告;东方电厂1号(2号)锅炉性能考核试验报告[R].西安热工研究院有限公司,2009.
  • 10秦建柱,黄莺,王长霞.华能东方电厂1号锅炉降低排烟温度技术改造可行性研究报告[R].华能东方电厂,2009.