摘要
分析了烟气排放连续监测系统(CEMS)在上传数据时出现数据误差的原因,提出了应尽可能将CEMS安装在较长的直段垂直烟道上,从而避免水雾、水滴和烟道变径等因素对测量结果的影响等解决措施。
The reason for data error during data upload in application of continuous emission monitoring system(CEMS) was investigated.Several measurements were put forward,like installing the CEMS on straight vertical flue duct as much as possible to avoid the effect of such factors as spray,water droplet and variable flue duct diameter on the measurement.
出处
《热力发电》
CAS
北大核心
2013年第5期80-82,共3页
Thermal Power Generation
关键词
CEMS
脱硫
污染物排放
数据误差
校验
CEMS
desulphurization
pollutant emission
data error
verification