摘要
主机为船舶最重要的动力设备,主机的安全运行直接关系并影响着整个船舶的安全。以17万t好望角型散货船在营运过程中停靠码头时,主机发生倒车故障的具体案例,详细描述了事件的发生经过,并通过对遥控操作系统及遥控换向相关关键部件空气分配器的工作原理进行阐述和分析,进而确定故障的实际原因并制定相应的解决方案。
As the most important marine equipment,the safe operation of main engine has a direct influence and relation to the safety of vessel. Taking the main engine astern failure occurred on the 177 000 DWT bulk carrier during berthed situation after delivery as an example,this paper clearly described the process of such problem. And by expatiating and analyzing the theory of air distribution unit which is the key component related to remote control system and remote reversing mechanism,this paper concluded the real reason of such problem and made a relevant solution.
出处
《船舶设计通讯》
2013年第1期41-43,共3页
Journal of Ship Design