摘要
本文介绍了一起大型汽轮发电机定子线棒层间温度高的故障,指出其原因系定子线棒堵塞引起的,并分析了堵塞物的成分和产生原因,同时提出了定冷水系统清洗的方法,为同类型机组提供宝贵的经验。
This paper introduces the fault of stator bars of large turbogenerator interpass temperature high,pointed out that the reason is the stator bar blockage,and analyzed the composition of blockage and causes,and puts forward the method of cleaning water system,provide the precious experience for the same type unit.
出处
《清洗世界》
CAS
2013年第9期44-47,共4页
Cleaning World
关键词
汽轮发电机
定子线棒
温度
堵塞
turbine generator
stator bar
temperature
blockage