小管径铜管在家用热泵热水器蒸发器中的应用研究 被引量:3

Research on Application of Smaller Diameter Copper Tube in Evaporator of Household Heat Pump Water Heater
下载PDF
导出
摘要 本文对家用热泵热水器蒸发器中以5 mm铜管替代目前最常用的9.52 mm铜管的可行性进行了研究和分析。采用现有的蒸发器计算模型设计了性能相当的两款蒸发器(9.52 mm铜管蒸发器和5 mm铜管蒸发器)并进行了对比分析,结果表明:5 mm铜管应用于家用热泵热水器蒸发器完全可以达到9.52 mm铜管蒸发器的换热性能,5 mm铜管蒸发器所需管材更少,重量更轻,成本更低。热泵热水器蒸发器采用小管径铜管,是降低成本、减轻重量、提升热泵热水器市场竞争力的有效手段。 The feasibility research was carried on replacing 9.52 mm copper tube with 5 mm copper tube in the evaporator of household heat pump water heater. Base on the present simulation mode, two types of evaporators(9.52 mm copper tube evaporator and 5 mm copper tube evaporator) were designed under the similar heat transfer performance. The cost of the two types of evaporators were analyzed. The research results indicated that less tubes, lighter weight and lower cost are needed for the 5 mm copper tube evaporator. Applying the smaller diameter copper tubes in the evaporator of heat pump water heater is an effective method to reduce the cost and weight and to enhance the market competiveness of heat pump water heater.
出处 《制冷技术》 2013年第3期21-23,共3页 Chinese Journal of Refrigeration Technology
关键词 小管径铜管 热泵热水器蒸发器 成本分析 Smaller diameter copper tube Evaporator in HPWH Cost analysis
  • 相关文献

参考文献9

  • 1李凡;赵恒谊;唐壁奎.空气源热泵热水器[M]{H}重庆:重庆大学出版社,20101-7.
  • 2周峰,马国远.空气能热泵热水器的现状及展望[J].节能,2006,25(7):13-16. 被引量:45
  • 3Wang CC,Lee CJ,Chang CT. Heat Transfer and Friction Correlation for Compact Louvered Fin-and-Tube Heat Exchangers[J].{H}International Journal of Heat and Mass Transfer,1998,(11):1945-1956.
  • 4Lee M,Kim Y,Lee H. Air-Side Heat Transfer Characteristics of Flat Plate Finned-Tube Heat Exchangers with Large Fin Pitches under Frosting Conditions[J].{H}International Journal of Heat and Mass Transfer,2010,(13-14):2655-2661.
  • 5Tao YB,He YL,Wu ZG. Three-Dimensional Numerical Study and Field Synergy Principle Analysis of Wavy Fin Heat Exchangers with Elliptic Tubes[J].{H}International Journal of Heat and Fluid Flow,2007,(06):1531-1544.
  • 6Shao L-L,Yang L,Zhang CL. Comparison of Heat Pump Performance Using Fin-and-Tube and Microchannel Heat Exchangers under Frost Conditions[J].{H}Applied Energy,2010,(04):1187-1197.
  • 7邓斌,陶文铨,林澜.蒸发器流程布置的数值模拟研究与分析[J].制冷学报,2006,27(1):28-33. 被引量:8
  • 8Wang CC,Lee WS,Sheu WJ. Empirical Airside Correlations of Fin-and-Tube Heat Exchangers under Dehumidifying Conditions[J].International Journal of Heat Exchangers,2001,(02):151-178.
  • 9刘志刚;刘咸定;赵冠春.工质热物理性质计算程序的编制及应用[M]{H}北京:科学出版社,1992.