期刊文献+

以3,4-二羟基肉桂酸为介质的多壁碳纳米管糊电极用于检测药物和尿液样品中的谷胱甘肽(英文) 被引量:3

Multiwall carbon nanotube paste electrode with 3,4-dihydroxy-cinnamic acid as mediator for the determination of glutathione in pharmaceutical and urine samples
下载PDF
导出
摘要 A sensitive and selective electrochemical sensor for the determination of glutathione(GSH) was developed using a modified multiwall carbon nanotube paste electrode with 3,4 dihydroxy cinnamic acid as a mediator.This modified electrode showed very high electrocatalytic activity for the anodic oxidation of GSH.Under the optimized conditions,the electrocatalytic peak current showed a linear relationship with GSH concentration in the range of 0.5-400.0 μmol/L with a detection limit of 0.1 μmol/L GSH.The relative standard deviations for seven successive assays of 5.0 and 25.0 μmol/L GSH were 2.2% and 2.7%,respectively.The modified electrode was used for the determination of GSH compounds in real urine samples. A sensitive and selective electrochemical sensor for the determination of glutathione(GSH) was developed using a modified multiwall carbon nanotube paste electrode with 3,4dihydroxycinnamic acid as a mediator.This modified electrode showed very high electrocatalytic activity for the anodic oxidation of GSH.Under the optimized conditions,the electrocatalytic peak current showed a linear relationship with GSH concentration in the range of 0.5–400.0 μmol/L with a detection limit of 0.1 μmol/L GSH.The relative standard deviations for seven successive assays of 5.0 and 25.0 μmol/L GSH were 2.2% and 2.7%,respectively.The modified electrode was used for the determination of GSH compounds in real urine samples.
出处 《催化学报》 CSCD 北大核心 2013年第10期1883-1889,共7页
基金 supported by Majlesi Branch,Islamic Azad University,Isfahan,Iran
关键词 GLUTATHIONE 3 4-Dihydroxy-cinnamic ACID CARBON PASTE ELECTRODE Multiwall CARBON NANOTUBE Sensor Glutathione 3,4-Dihydroxy-cinnamic acid Carbon paste electrode Multiwall carbon nanotube Sensor
  • 相关文献

参考文献47

  • 1Sadegh Salmanpour,Toktam Tavana,Ali Pahlavan,Mohammad A. Khalilzadeh,Ali A. Ensafi,Hassan Karimi-Maleh,Hadi Beitollahi,Elaheh Kowsari,Daryoush Zareyee.Voltammetric determination of norepinephrine in the presence of acetaminophen using a novel ionic liquid/multiwall carbon nanotubes paste electrode[J]Materials Science & Engineering C,2012(7).
  • 2Toktam Tavana,Mohammad A. Khalilzadeh,Hassan Karimi-Maleh,Ali A. Ensafi,Hadi Beitollahi,Daryoush Zareyee.Sensitive voltammetric determination of epinephrine in the presence of acetaminophen at a novel ionic liquid modified carbon nanotubes paste electrode[J]Journal of Molecular Liquids,2012.
  • 3A.A. Ensafi,H. Karimi-Maleh,S. Mallakpour,B. Rezaei.Highly sensitive voltammetric sensor based on catechol-derivative-multiwall carbon nanotubes for the catalytic determination of captopril in patient human urine samples[J]Colloids and Surfaces B: Biointerfaces,2011(2).
  • 4Ali A. Ensafi,M. Taei,T. Khayamian,H. Karimi-Maleh,F. Hasanpour.Voltammetric measurement of trace amount of glutathione using multiwall carbon nanotubes as a sensor and chlorpromazine as a mediator[J]Journal of Solid State Electrochemistry,2010(8).
  • 5Ali A. Ensafi,H. Karimi-Maleh.Modified multiwall carbon nanotubes paste electrode as a sensor for simultaneous determination of 6-thioguanine and folic acid using ferrocenedicarboxylic acid as a mediator[J]Journal of Electroanalytical Chemistry,2010(1).
  • 6Jahan Bakhsh Raoof,Reza Ojani,Mansureh Kolbadinezhad.Voltammetric sensor for glutathione determination based on ferrocene-modified carbon paste electrode[J]Journal of Solid State Electrochemistry,2009(9).
  • 7J. B. Raoof,R. Ojani,H. Karimi-Maleh.Electrocatalytic oxidation of glutathione at carbon paste electrode modified with 2,7-bis (ferrocenyl ethyl) fluoren-9-one: application as a voltammetric sensor[J]Journal of Applied Electrochemistry,2009(8).
  • 8A.A. Ensafi,T. Khayamian,F. Hasanpour.Determination of glutathione in hemolysed erythrocyte by flow injection analysis with chemiluminescence detection[J]Journal of Pharmaceutical and Biomedical Analysis,2008(1).
  • 9Rajendra N. Goyal,Vinod K. Gupta,Sanghamitra Chatterjee.Simultaneous determination of adenosine and inosine using single-wall carbon nanotubes modified pyrolytic graphite electrode[J]Talanta,2008(3).
  • 10Percy Calvo-Marzal,Karin Y. Chumbimuni-Torres,Nelci Fenalti H?ehr,Lauro T. Kubota.Determination of glutathione in hemolysed erythrocyte with amperometric sensor based on TTF-TCNQ[J]Clinica Chimica Acta,2006(1).

共引文献11

同被引文献6

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部