摘要 本文以符合ISO 12233标准的测试图和专业图像质量分析软件测量了可移动扫描仪的空间频率响应。与平台式扫描仪测量数据的比较表明,可移动扫描仪的综合性能占优。 In this paper, spatial frequency response of a movable scanner was measured using standard test target and professional image quality analysis software conforming to the ISO 12233 standard. It is show that comprehensive performances of the movable scanner are better then that of platform scanner by comparing the measured data of the spatial frequency response from the two image capturing equipment.
作者 姚海根
出处 《出版与印刷》 2013年第2期2-5,共4页 Publishing & Printing
关键词 可移动扫描仪 空间频率响应 平台式扫描仪 Movable Scanner Spatial Frequency Response Platform Scanner
  • 相关文献

参考文献1

二级参考文献4

  • 1ISO 12233 : 2000. Photography-Electronic Still-Picture Cameras-Resolution Measurements[S]. Switzerland, Geneva: ISO, 2000.
  • 2WILLIAMS Don. Debunking of Specsmanship: Progress on ISO/TC42 Standards for Digital Capture Imaging Performance[C]// Proceedings of IS&T's 2003 PICS Conference. Springfield, USA: IS&T, 2003:77-81.
  • 3WUELLER Dietmar, LOEBICH Christian. Practical Scanner Tests Based on OECF and SFR Measurements[ C]//Proceedings of the Image Processing, Image Quality, Image Capture Systems Conference. Springfield, USA: IS&T, 2001 : 252 -256.
  • 4Norman Koren. DigitUnderstanding image sharpness part 1 : Introduction to resolution and MTF curves[EB/OL]. (2007 - 02 - 26 ). http: //www. normankoren, com/Tutorials/ MTF. html#MTFintro.