Sedation and monitoring for gastrointestinal endoscopy 被引量:5

Sedation and monitoring for gastrointestinal endoscopy
下载PDF
导出
摘要 The safe sedation of patients for diagnostic or therapeutic procedures requires a combination of properly trained physicians and suitable facilities.Additionally,appropriate selection and preparation of patients,suitable sedative technique,application of drugs,adequate monitoring,and proper recovery of patients is essential.The goal of procedural sedation is the safe and effective control of pain and anxiety as well as to provide an appropriate degree of memory loss or decreased awareness.Sedation practices for gastrointestinal endoscopy(GIE) vary widely.The majority of GIE patients are ambulatory cases.Most of this procedure requires a short time.So,short acting,rapid onset drugs with little adverse effects and improved safety profiles are commonly used.The present review focuses on commonly used regimens and monitoring practices in GIE sedation.This article is to discuss the decision making process used to determine appropriate pre-sedation assessment,monitoring,drug selection,dose of sedative agents,sedation endpoint and post-sedation care.It also reviews the current status of sedation and monitoring for GIE procedures in Thailand. The safe sedation of patients for diagnostic or therapeutic procedures requires a combination of properly trained physicians and suitable facilities.Additionally,appropriate selection and preparation of patients,suitable sedative technique,application of drugs,adequate monitoring,and proper recovery of patients is essential.The goal of procedural sedation is the safe and effective control of pain and anxiety as well as to provide an appropriate degree of memory loss or decreased awareness.Sedation practices for gastrointestinal endoscopy(GIE) vary widely.The majority of GIE patients are ambulatory cases.Most of this procedure requires a short time.So,short acting,rapid onset drugs with little adverse effects and improved safety profiles are commonly used.The present review focuses on commonly used regimens and monitoring practices in GIE sedation.This article is to discuss the decision making process used to determine appropriate pre-sedation assessment,monitoring,drug selection,dose of sedative agents,sedation endpoint and post-sedation care.It also reviews the current status of sedation and monitoring for GIE procedures in Thailand.
出处 《World Journal of Gastrointestinal Endoscopy》 CAS 2013年第2期47-55,共9页 世界胃肠内镜杂志(英文版)(电子版)
关键词 SEDATION MONITORING GASTROINTESTINAL ENDOSCOPY SEDATIVES ANALGESICS Sedation Monitoring Gastrointestinal endoscopy Sedatives Analgesics
  • 相关文献

参考文献2

二级参考文献20

  • 1Digestive Department (Chen WX, Lin HJ, Gu Q, Zhong XQ, Yu CH, Li YM and Gu ZY) and Department of Intensive Care Unit (Zhang WF), First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003 , China.Sedation and safety of propofol for therapeutic endoscopic retrograde cholangiopancreatography[J].Hepatobiliary & Pancreatic Diseases International,2005,4(3):437-440. 被引量:10
  • 2Wehrmann T,Kokabpick S,lembcke B,et al.Efficacy and safety of intravenous propofol sedation during routine ERCP: a prospective, controlled study. Gastrointestinal Endoscopy . 1999
  • 3Jung M,Hofmann C,Kiesslich R,Brackertz A.Improved sedation in diagnostic and therapeutic ERCP: propofol is an alternative to midazolam. Endoscopy . 2000
  • 4Wehrmann T,,Grotkamp J,Stergiou N,Riphaus A,Kluge A,Lembcke B,Schultz A.Electroencephalogram monitoring facilitates sedation with propofol for routine ERCP:a rando-mized,controlled trial. Gastrointestinal Endoscopy . 2002
  • 5American Society of Anesthesiologists Task Force on Se- dation and Analgesia by Non-Anesthesiologists.Practice guidelines for sedation and analgesia by non-anesthesiolo- gists. Anesthesiology . 2002
  • 6W. Wilhelm,S. Kreuer,R. Larsen.Narcotrend-EEG-Monitoring bei total intraven?ser An?sthesie[J]. Der Anaesthesist . 2002 (12)
  • 7S. Kreuer,A. Biedler,R. Larsen,S. Schoth,S. Altmann,W. Wilhelm.The Narcotrend?– a new EEG monitor designed to measure the depth of anaesthesia A comparison with bispectral index monitoring during propofol-remifentanil-anaesthesia[J]. Der Anaesthesist . 2001 (12)
  • 8Peacock JE,Lewis RP,Reilly CS,Nimmo WS.Effect of different rates of infusion of propofol for induction of anaesthesia in elderly patients. British Journal of Anaesthesia . 1990
  • 9Amornyotin S,Suraseranivongse S,Muangman S,Sattawa- tthamrong Y,Tensit K,Prakotsue K,et al.Comparison of dose requirement of diluted and undiluted propofol for patients undergoing ERCP. Thai J Anesthesiol . 2003
  • 10Kreuer S,Bruhn J,Larsen R,Bialas P,Wilhelm W.Comparability of Narcotrend index and bispectral index during propofol anaesthesia. British Journal of Anaesthesia . 2004

共引文献21

同被引文献59

引证文献5

二级引证文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部