期刊文献+

Radiation dose reduction with application of non-linear adaptive filters for abdominal CT 被引量:3

下载PDF
导出
摘要 AIM:To evaluate the effect of non-linear adaptive filters (NLAF) on abdominal computed tomography (CT) images acquired at different radiation dose levels.METHODS:Nineteen patients (mean age 61.6 ± 7.9 years,M:F=8:11) gave informed consent for an Institutional Review Board approved prospective study involving acquisition of 4 additional image series (200,150,100,50 mAs and 120 kVp) on a 64 slice multidetector row CT scanner over an identical 10 cm length in the abdomen.The CT images acquired at 150,100 and 50 mAs were processed with the NLAF.Two radiologists reviewed unprocessed and processed images for image quality in a blinded randomized manner.CT dose index volume,dose length product,patient weight,transverse diameters,objective noise and CT numbers wererecorded.Data were analyzed using Analysis of Variance and Wilcoxon signed rank test.RESULTS:Of the 31 lesions detected in abdominal CT images,28 lesions were less than 1 cm in size.Subjective image noise was graded as unacceptable in unprocessed images at 50 and 100 mAs,and in NLAF processed images at 50 mAs only.In NLAF processed images,objective image noise was decreased by 21% (14.4 ± 4/18.2 ± 4.9) at 150 mAs,28.3% (15.7 ± 5.6/21.9 ± 4) at 100 mAs and by 39.4% (18.8 ± 9/30.4 ± 9.2) at 50 mAs compared to unprocessed images acquired at respective radiation dose levels.At 100 mAs the visibility of smaller structures improved from suboptimal in unprocessed images to excellent in NLAF processed images,whereas diagnostic confidence was respectively improved from probably confident to fully confident.CONCLUSION:NLAF lowers image noise,improves the visibility of small structures and maintains lesion conspicuity at down to 100 mAs for abdominal CT. AIM: To evaluate the effect of non-linear adaptive filters (NLAF) on abdominal computed tomography (CT) images acquired at different radiation dose levels. METHODS: Nineteen patients (mean age 61.6 ± 7.9 years, M:F = 8:11) gave informed consent for an Institutional Review Board approved prospective study involving acquisition of 4 additional image series (200, 150, 100, 50 mAs and 120 kVp) on a 64 slice multidetector row CT scanner over an identical 10 cm length in the abdomen. The CT images acquired at 150, 100 and 50 mAs were processed with the NLAF. Two radiologists reviewed unprocessed and processed images for image quality in a blinded randomized manner. CT dose index volume, dose length product, patient weight, transverse diameters, objective noise and CT numbers were recorded. Data were analyzed using Analysis of Variance and Wilcoxon signed rank test. RESULTS: Of the 31 lesions detected in abdominal CT images, 28 lesions were less than 1 cm in size. Subjective image noise was graded as unacceptable in unprocessed images at 50 and 100 mAs, and in NLAF processed images at 50 mAs only. In NLAF processed images, objective image noise was decreased by 21% (14.4 ± 4/18.2 ± 4.9) at 150 mAs, 28.3% (15.7 ± 5.6/21.9 ± 4) at 100 mAs and by 39.4% (18.8 ± 9/30.4 ± 9.2) at 50 mAs compared to unprocessed images acquired at respective radiation dose levels. At 100 mAs the visibility of smaller structures improved from suboptimal in unprocessed images to excellent in NLAF processed images, whereas diagnostic confidence was respectively improved from probably confident to fully confident. CONCLUSION: NLAF lowers image noise, improves the visibility of small structures and maintains lesion conspicuity at down to 100 mAs for abdominal CT.
出处 《World Journal of Radiology》 CAS 2012年第1期21-28,共8页 世界放射学杂志(英文版)(电子版)
关键词 Noise REDUCTION FILTERS COMPUTED TOMOGRAPHY radiation dose REDUCTION ABDOMINAL COMPUTED TOMOGRAPHY image quality NON-LINEAR adaptive FILTERS Noise reduction filters Computed tomography radiation dose reduction Abdominal computed tomography image quality Non-linear adaptive filters
  • 相关文献

参考文献24

  • 1S.Singh,M.K.Kalra,J.Hsieh,P.E.Licato,S.Do,H.H.Pien,于晓坤.腹部CT:迭代统计重建法与滤波反投影重建技术的比较[J].国际医学放射学杂志,2011(1). 被引量:7
  • 2S.Singh,M.K.Kalra,M.A.Moore,R.Shailam,B.Liu,T.L.Toth,秦乃姗.适应患儿大小、临床指征和既往检查次数的小儿CT扫描参数降低剂量及其依从性的研究[J].国际医学放射学杂志,2009,32(5):489-489. 被引量:42
  • 3Yoshinori Funama,Kazuo Awai,Osamu Miyazaki,Taiga Goto,Yoshiharu Nakayama,Masamitchi Shimamura,Kumiko Hiraishi,Shinichi Hori,Yasuyuki Yamashita.Radiation dose reduction in hepatic multidetector computed tomography with a novel adaptive noise reduction filter[J]. Radiation Medicine . 2008 (3)
  • 4Rizzo SM,Kalra MK,Schmidt B,Raupach R,Maher MM,Blake MA,Saini S.CT images of abdomen and pelvis: effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics. Radiology . 2005
  • 5Sato K,Goto M,Ishiya H,Oshita R,Mori I,Yanagawa I.[Evaluation of non-linear adaptive smoothing filter by digi- tal phantom]. Nihon Hoshasen Gijutsu Gakkai Zasshi . 2008
  • 6Kr pil P,Lanzman RS,Walther C,R hlen S,Godehardt E,M dder U,Cohnen M.[Dose reduction and image quality in MDCT of the upper abdomen: potential of an adaptive post- processing filter]. Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin . 2010
  • 7European guidelines on quality criteria for com- puted tomography. EUR 16262 .
  • 8Singh S,Kalra MK,Gilman MD,Hsieh J,Pien HH,Digum- arthy SR,Shepard JA.Adaptive statistical iterative recon- struction technique for radiation dose reduction in chest CT: a pilot study. Radiology . 2011
  • 9Department of Health and Human Services.What’’s NEXT Nationwide Evaluation of X-ray Trends: 2000 computed tomography. Conference of Radiation Control Program Directors . 2006
  • 10Guthrie C.How dangerous are CT scans Time Magazine. http://www.time.com/time/health/article/0,8599,1818520,00.html . 2008