摘要 AIM: To evaluate the sources of variation influencing the microvascularization parameters measured by dynamic contrast-enhanced ultrasonography (DCE-US). METHODS: Firstly, we evaluated, in vitro , the impact of the manual repositioning of the ultrasound probe and the variations in flow rates. Experiments were conducted using a custom-made phantom setup simulating a tumor and its associated arterial input. Secondly, we evaluated, in vivo , the impact of multiple contrast agent injections and of examination day, as well as the influence of the size of region of interest (ROI) associated with the arterial input function (AIF). Experiments were conducted on xenografted B16F10 female nude mice. For all of the experiments, an ultrasound scanner along with a linear transducer was used to perform pulse inversion imaging based on linear raw data throughout the experiments. Semi-quantitative and quantitative analyses were performed using two signal-processing methods. RESULTS:In vitro , no microvascularization parameters, whether semi-quantitative or quantitative, were significantly correlated (P values from 0.059 to 0.860) with the repositioning of the probe. In addition, all semiquantitative microvascularization parameters were correlated with the flow variation while only one quantitative parameter, the tumor blood flow, exhibited P value lower than 0.05 (P = 0.004). In vivo , multiple contrast agent injections had no significant impact (P values from 0.060 to 0.885) on microvascularization parameters. In addition, it was demonstrated that semi-quantitative microvascularization parameters were correlated with the tumor growth while among the quantitative parameters, only the tissue blood flow exhibited P value lower than 0.05 (P = 0.015). Based on these results, it was demonstrated that the ROI size of the AIF had significant influence on microvascularization parameters: in the context of larger arterial ROI (from 1.17 ± 0.6 mm 3 to 3.65 ± 0.3 mm 3 ), tumor blood flow and tumor blood volume were correlated with the tumor growth, exhibiting P values lower than 0.001. CONCLUSION: AIF selection is an essential aspect of the deconvolution process to validate the quantitative DCE-US method. AIM: To evaluate the sources of variation influencing the microvascularization parameters measured by dynamic contrast-enhanced ultrasonography (DCE-US).
出处 《World Journal of Radiology》 CAS 2012年第7期291-301,共11页 世界放射学杂志(英文版)(电子版)
关键词 DYNAMIC CONTRAST-ENHANCED ULTRASONOGRAPHY ANGIOGENESIS Linear RAW data ARTERIAL input function Functional imaging Dynamic contrast-enhanced ultrasonography Angiogenesis Linear raw data Arterial input function Functional imaging
  • 相关文献

参考文献51

  • 1Yerlikaya A,Erin N.Differential sensitivity of breast cancer and melanoma cells to proteasome inhibitor Velcade. International Journal of Molecular Medicine . 2008
  • 2Rumboldt Z,Al-Okaili R,Deverkis JP.Perfusion CT for head and neck tumors: pilot study. American Journal of Neuroradiology . 2005
  • 3Miller JC,Pien HH,Sahani D,et al.Imaging angiogenesis: applications and potential for drug development. Journal of the National Cancer Institute . 2005
  • 4Schneider M.Characteristics of Sono Vuetrade markEchocardiography,1999.
  • 5Quaia E,Calliada F,Bertolotto M,et al.Characterization of focal liver lesions with contrast-specific US modes and a sulfur hexafluoride-filled microbubble contrast agent: diagnostic performance and confidenceRadiology,2004.
  • 6von Herbay A,Vogt C,Willers R,et al.Real-time imaging with the sonographic contrast agent SonoVue: differentiation between benign and malignant hepatic lesions. Journal of Ultrasound in Medicine . 2004
  • 7Burns PN,Wilson SR,Simpson DH.Pulse inversion imaging of liver blood flow: improved method for characterizing focal masses with microbubble contrast. Investigative Radiology . 2000
  • 8Verbeek X A,Willigers J M,Prinzen F W,et al.High-resolution functional imaging with ultrasound contrast agents based on RF processing in an in vivo kidney experiment. Journal of Ultrasound in Medicine . 2001
  • 9de Marco G,Dassonvalle P,,M.C. H-F,Onen F,Idy-Peretti I.Cerebral perfusion: dynamic suceptibility contrast MR imaging. Part 2: vascular models and data extraction. Med Nucl . 2004
  • 10Cenic A,Nabavi DG,Craen RA,et al.Dynamic CT measurement of cerebral blood flow :a validation study. AJNR - American Journal of Neuroradiology . 1999

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部