期刊文献+

Feasibility study of computed vs measured high b-value(1400 s/mm2) diffusion-weighted MR images of the prostate 被引量:5

Feasibility study of computed vs measured high b-value(1400 s/mm2) diffusion-weighted MR images of the prostate
下载PDF
导出
摘要 AIM: To evaluate the impact of computed b = 1400 s/mm2(C-b1400) vs measured b = 1400 s/mm2(M-b1400) diffusion-weighted images(DWI) on lesion detection rate, image quality and quality of lesion demarcation using a modern 3T-MR system based on a small-field-of-view sequence(sFOV). METHODS: Thirty patients(PSA: 9.5 ± 8.7 ng/mL; 68 ± 12 years) referred for magnetic resonance imaging(MRI) of the prostate were enrolled in this study. All measurements were performed on a 3T MR system.For DWI, a single-shot EPI diffusion sequence(b = 0, 100, 400, 800 s/mm2) was utilized. C-b1400 was cal-culated voxelwise from the ADC and diffusion images. Additionally, M-b1400 was acquired for evaluation and comparison. Lesion detection rate and maximum lesion diameters were obtained and compared. Image quality and quality of lesion demarcation were rated accord-ing to a 5-point Likert-type scale. Ratios of lesion-to-bladder as well as prostate-to-bladder signal intensity(SI) were calculated to estimate the signal-to-noise-ratio(SNR). RESULTS: Twenty-four lesions were detected on M-b1400 images and compared to C-b1400 images. C-b1400 detected three additional cancer suspicious lesions. Overall image quality was rated significantly better and SI ratios were significantly higher on C-b1400(2.3 ± 0.8 vs 3.1 ± 1.0, P < 0.001; 5.6 ± 1.8 vs 2.8 ± 0.9, P < 0.001). Comparison of lesion size showed no significant differences between C- and M-b1400(P = 0.22). CONCLUSION: Combination of a high b-value extrap-olation and sFOV may contribute to increase diagnostic accuracy of DWI without an increase of acquisition time, which may be useful to guide targeted prostate biopsies and to improve quality of multiparametric MRI(mMRI) especially under economical aspects in a pri-vate practice setting. AIM: To evaluate the impact of computed b = 1400 s/mm2(C-b1400) vs measured b = 1400 s/mm2(M-b1400) diffusion-weighted images(DWI) on lesion detection rate, image quality and quality of lesion demarcation using a modern 3T-MR system based on a small-field-of-view sequence(sFOV). METHODS: Thirty patients(PSA: 9.5 ± 8.7 ng/mL; 68 ± 12 years) referred for magnetic resonance imaging(MRI) of the prostate were enrolled in this study. All measurements were performed on a 3T MR system.For DWI, a single-shot EPI diffusion sequence(b = 0, 100, 400, 800 s/mm2) was utilized. C-b1400 was cal-culated voxelwise from the ADC and diffusion images. Additionally, M-b1400 was acquired for evaluation and comparison. Lesion detection rate and maximum lesion diameters were obtained and compared. Image quality and quality of lesion demarcation were rated accord-ing to a 5-point Likert-type scale. Ratios of lesion-to-bladder as well as prostate-to-bladder signal intensity(SI) were calculated to estimate the signal-to-noise-ratio(SNR). RESULTS: Twenty-four lesions were detected on M-b1400 images and compared to C-b1400 images. C-b1400 detected three additional cancer suspicious lesions. Overall image quality was rated significantly better and SI ratios were significantly higher on C-b1400(2.3 ± 0.8 vs 3.1 ± 1.0, P < 0.001; 5.6 ± 1.8 vs 2.8 ± 0.9, P < 0.001). Comparison of lesion size showed no significant differences between C- and M-b1400(P = 0.22). CONCLUSION: Combination of a high b-value extrap-olation and sFOV may contribute to increase diagnostic accuracy of DWI without an increase of acquisition time, which may be useful to guide targeted prostate biopsies and to improve quality of multiparametric MRI(mMRI) especially under economical aspects in a pri-vate practice setting.
出处 《World Journal of Radiology》 CAS 2014年第6期374-380,共7页 世界放射学杂志(英文版)(电子版)
关键词 前列腺癌症 磁性的回声成像 散开加权的成像 超离频 b 外推的 b Prostate cancer Magnetic resonance imag-ing Diffusion-weighted imaging Ultra-high b-values Extrapolated b-values
  • 相关文献

参考文献13

  • 1T.Metens,D.Miranda,J.Absil,C.Matos,范璐.3 T MR扩散加权成像描述前列腺癌的最佳b值是什么?[J].国际医学放射学杂志.2012(03)
  • 2林海雪.电能质量国家标准系列讲座 第5讲 三相电压不平衡标准[J].建筑电气,2011,30(10):25-29. 被引量:8
  • 3孙美玉,B. Turkbey,P.A. Pinto,H. Mani,M. Bernardo,Y.L. Mckinney.3T MR多参数成像对前列腺癌检测价值与病理组织学对照研究[J].国际医学放射学杂志.2010(03)
  • 4Andrew B. Rosenkrantz,Eric E. Sigmund,Glyn Johnson,James S. Babb,Thais C. Mussi,Jonathan Melamed,Samir S. Taneja,Vivian S. Lee,Jens H. Jensen.Prostate Cancer: Feasibility and Preliminary Experience of a Diffusional Kurtosis Model for Detection and Assessment of Aggressiveness of Peripheral Zone Cancer[J].Radiology.2012(1)
  • 5Sung Yoon Park,Chan Kyo Kim,Byung Kwan Park,Won Park,Hee Chul Park,Deok Hyun Han,Bohyun Kim.Early Changes in Apparent Diffusion Coefficient From Diffusion-Weighted MR Imaging During Radiotherapy for Prostate Cancer[J].International Journal of Radiation Oncology Biology Physics.2012(2)
  • 6Yoshimitsu Ohgiya,Jumpei Suyama,Noritaka Seino,Takashi Hashizume,Masaaki Kawahara,Syouei Sai,Makoto Saiki,Jiro Munechika,Masanori Hirose,Takehiko Gokan.Diagnostic accuracy of ultra-high- b -value 3.0-T diffusion-weighted MR imaging for detection of prostate cancer[J].Clinical Imaging.2012(5)
  • 7Jelle O. Barentsz,Jonathan Richenberg,Richard Clements,Peter Choyke,Sadhna Verma,Geert Villeirs,Olivier Rouviere,Vibeke Logager,Jurgen J. Fütterer.ESUR prostate MR guidelines 2012[J].European Radiology.2012(4)
  • 8Diederik M. Somford,Thomas Hambrock,Christina A. Hulsbergen-van de Kaa,Jurgen J. Fütterer,Inge M. van Oort,Jean-Paul van Basten,Herbert F. Karthaus,J. Alfred Witjes,Jelle O. Barentsz.Initial Experience With Identifying High-Grade Prostate Cancer Using Diffusion-Weighted MR Imaging (DWI) in Patients With a Gleason Score ≤3 + 3 = 6 Upon Schematic TRUS-Guided Biopsy: A Radical Prostatectomy Correlated Series[J].Investigative Radiology.2012(3)
  • 9T. Metens,D. Miranda,J. Absil,C. Matos.What is the optimal b value in diffusion-weighted MR imaging to depict prostate cancer at 3T?[J].European Radiology.2012(3)
  • 10Otis Brawley.Prostate cancer epidemiology in the United States[J].World Journal of Urology.2012(2)

二级参考文献3

  • 1电力工业部电力科学研究院高压研究所.DL/T620-1997交流电气装置的过电压保护和绝缘配合[S].北京:中国电力出版社.1997.
  • 2武汉国测科技股份有限公司,中国电力科学研究院,中机生产力促进中心.等起草.GB/T15543-2008电能质量三相电压不平衡[S].北京:中国标准出版社,2009.
  • 3International Electrotechnica Commission. IEC 61000 - 4 - 30 Electromagnetic compatibility (EMC) -- Part 4 - 30: Testing and measurement techniques -- Power quality measurement methods [S ]. Geneva.

共引文献7

同被引文献13

引证文献5

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部