摘要 AIM:To validate the sleep-disordered breathing components of a portable electrocardiography and hemodynamic monitor to be used for sleep apnea screening.METHODS:Sleep-disordered breathing(SDB) is associated with cardiovascular disease.Patients with existing cardiovascular disease may have unrecognized SDB or may develop SDB while under the care of a cardiologist.A screening device for SDB,easy to use and appealing to cardiologists,would assist in referral of appropriate patients for full polysomnography(PSG).A cardiac and respiratory monitor(CPAM) was attached to patients undergoing PSG and an apnea/hypopnea index(AHI) generated.The CPAM device produced respiration rate,snoring rate,individual apnea/hypopnea events and an SDB severity score(SDBSS).In addition to AHI,an expert over-reader annotated individual breaths,snores and SDB breathing events to which the automated algorithms were compared.RESULTS:The test set consisted of data from 85 patients(age:50.5 ± 12.4 years).Of these,57 had a positive PSG defined as AHI ≥ 5.0(mean:30.0 ± 29.8,negative group mean:1.5 ± 1.2).The sensitivity and specificity of the SDBSS compared to AHI was 57.9% and 89.3%,respectively.The correlation of snoring rate by CPAM compared to the expert overreader was r = 0.58(mean error:1.52 snores/min),while the automated respiration rate had a correlation of r = 0.90(mean error:0.70 breaths/min).CONCLUSION:This performance assessment shows that CPAM can be a useful portable monitor for screening and follow-up of subjects for SDB. AIM: To validate the sleep-disordered breathing components of a portable electrocardiography and hemodynamic monitor to be used for sleep apnea screening. METHODS: Sleep-disordered breathing (SDB) is associated with cardiovascular disease. Patients with existing cardiovascular disease may have unrecognized SDB or may develop SDB while under the care of a cardiologist. A screening device for SDB, easy to use and appealing to cardiologists, would assist in referral of appropriate patients for full polysomnography (PSG). A cardiac and respiratory monitor (CPAM) was attached to patients undergoing PSG and an apnea/hypopnea index (AHI) generated. The CPAM device produced respiration rate, snoring rate, individual apnea/hypopnea events and an SDB severity score (SDBSS). In addition to AHI, an expert over-reader annotated individual breaths, snores and SDB breathing events to which the automated algorithms were compared. RESULTS: The test set consisted of data from 85 patients (age: 50.5 ± 12.4 years). Of these, 57 had a positive PSG defined as AHI ≥ 5.0 (mean: 30.0 ± 29.8, negative group mean: 1.5 ± 1.2). The sensitivity and specificity of the SDBSS compared to AHI was 57.9% and 89.3%, respectively. The correlation of snoring rate by CPAM compared to the expert over-reader was r = 0.58 (mean error: 1.52 snores/min), while the automated respiration rate had a correlation of r = 0.90 (mean error: 0.70 breaths/min). CONCLUSION: This performance assessment shows that CPAM can be a useful portable monitor for screening and follow-up of subjects for SDB.
出处 《World Journal of Cardiology》 CAS 2012年第4期121-127,共7页 世界心脏病学杂志(英文版)(电子版)
基金 Supported by An equipment grant from Inovise Medical,Inc.,Beaverton OR,United States,for clinical data collection
关键词 Portable MONITOR Sleep-disordered BREATHING POLYSOMNOGRAPHY SLEEP APNEA HEMODYNAMIC MONITOR Portable monitor Sleep-disordered breathing Polysomnography Sleep apnea Hemodynamic monitor
  • 相关文献

参考文献25

  • 1Young T;Palta M;Dempsey J.The occurrence of sleep-disordered breathing among middle-aged adults,1993(17).
  • 2Young T,Evans L,Finn L,et al.Estimation of the clinically diagnosed proportion of sleep apnea syndrome in middle-aged men and women. Sleep . 1997
  • 3Fung JW,Li TS,Choy DK,et al.Severe obstructive sleep apnea is associated with left ventricular diastolic dysfunction. Chest . 2002
  • 4Ferreira S,Marinho A,Patacho M,Santa-Clara E,Carrondo C,Winck J, et al.Prevalence and characteristics of sleep apnoea in patients with stable heart failure: Results from a heart failure clinic. BMC Pulm Med . 2010
  • 5VK Somers,DP White,R Amin,WT Abraham,F Costa,A Culebras,S Daniels,JS Floras,CE Hunt,LJ Olson,TG Pickering,R Russell,M Woo,T Young.Sleep apnea and cardiovascular disease: an American Heart Association/american College of Cardiology Foundation Scientific Statement from the American Heart Association Council for High Blood Pressure Research Professional Education Committee, Council on. Circulation . 2008
  • 6NA Collop,WM Anderson,B Boehlecke,D Claman,R Goldberg,DJ Gottlieb,D Hudgel,M Sateia,R Schwab.Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable Monitoring Task Force of the American Academy of Sleep Medicine. J Clin Sleep Med . 2007
  • 7Roos M,Toggweiler S,Jamshidi P,Zuber M,Kobza R,Meier R,Erne P.Noninvasive detection of left ventricular systolic dysfunction by acoustic cardiography in cardiac failure patients. Journal of Cardiac Failure . 2008
  • 8Shah SJ,Michaels AD.Hemodynamic correlates of the third heart sound and systolic time intervals. Congestive Heart Failure . 2006
  • 9Erne P.Beyond auscultation--acoustic cardiography in the diagnosis and assessment of cardiac disease. Swiss Medical Weekly . 2008
  • 10S. Javaheri,R. Shukla,H. Zeigler,L. Wexler.Central sleep apnea, right ventricular dysfunction, and low diastolic blood pressure are predictors of mortality in systolic heart failure. Journal of the American College of Cardiology . 2007

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部