期刊文献+

Longitudinal stent compression of everolimus-eluting stent: A report of 2 cases 被引量:1

Longitudinal stent compression of everolimus-eluting stent: A report of 2 cases
下载PDF
导出
摘要 Second generation drug eluting stents(DES) have shown better safety and efficacy in comparison to first generation DES,because of thinner struts,nondurable polymers and coating with better anti-proliferative drugs.The newer DES with cobalt alloy base have demonstrated a greater trackability,deliverability,conformability,flexibility and radio-opacity.However,these thin strut stents have a downside of poor longitudinal axial strength,and therefore get easily deformed/ compressed at their end with a slight trauma during exchange of various catheters.We hereby report two cases of "longitudinal stent compression(LSC)" of everolimus-eluting stent,which happened during percutaneous coronary intervention of right coronary artery.Both the cases were successfully managed with non-compliant balloon dilatation.Various reasons for LSC and its management are discussed in the article. Second generation drug eluting stents(DES) have shown better safety and efficacy in comparison to first generation DES,because of thinner struts,nondurable polymers and coating with better anti-proliferative drugs.The newer DES with cobalt alloy base have demonstrated a greater trackability,deliverability,conformability,flexibility and radio-opacity.However,these thin strut stents have a downside of poor longitudinal axial strength,and therefore get easily deformed/ compressed at their end with a slight trauma during exchange of various catheters.We hereby report two cases of "longitudinal stent compression(LSC)" of everolimus-eluting stent,which happened during percutaneous coronary intervention of right coronary artery.Both the cases were successfully managed with non-compliant balloon dilatation.Various reasons for LSC and its management are discussed in the article.
出处 《World Journal of Cardiology》 CAS 2013年第8期313-316,共4页 世界心脏病学杂志(英文版)(电子版)
关键词 COMPLICATION Everolimus-eluting STENT Longitudinal STENT compression PERCUTANEOUS CORONARY intervention STENT structure STENT deformation Complication Everolimus-eluting stent Longitudinal stent compression Percutaneous coronary intervention Stent structure Stent deformation
  • 相关文献

参考文献9

  • 1David Planer,Pieter C. Smits,Dean J. Kereiakes,Elvin Kedhi,Martin Fahy,Ke Xu,Patrick W. Serruys,Gregg W. Stone.Comparison of Everolimus- and Paclitaxel-Eluting Stents in Patients With Acute and Stable Coronary Syndromes[J]. JACC: Cardiovascular Interventions . 2011 (10)
  • 2John A. Ormiston,Bruce Webber,Mark W.I. Webster.Stent Longitudinal Integrity[J]. JACC: Cardiovascular Interventions . 2011 (12)
  • 3Shannon J,Latib A,Takagi K,Chieffo A,Figini F,Sacco F,Ferrarello S,Montorfano M,Colombo A."Procedural trauma risks longitudinal shortening of the Promus Element stent platform". Catheterization and Cardiovascular Interventions . 2013
  • 4Leibundgut G,Gick M,Toma A,Valina C,L ffelhardt N,Büttner HJ,Neumann FJ.Longitudinal compression of the platinum-chromium everolimus-eluting stent during coronary implantation:predisposing mechanical properties,incidence,and predictors in a large patient cohort. Catheterization and Cardiovascular Interventions . 2013
  • 5Hanratty CG,Walsh SJ.Longitudinal compression:a"new"complication with modern coronary stent platforms--time to think beyond deliverability. EuroIntervention . 2011
  • 6Williams PD,Mamas MA,Morgan KP,El-Omar M,Clarke B,Bainbridge A,Fath-Ordoubadi F,Fraser DG.Longitudinal stent deformation:a retrospective analysis of frequency and mechanisms. EuroIntervention . 2012
  • 7Prabhu S,Schikorr T,Mahmoud T,Jacobs J,Potgieter A,Simonton C.Engineering assessment of the longitudinal compression behaviour of contemporary coronary stents. EuroIntervention . 2012
  • 8Finet G,Rioufol G.Coronary stent longitudinal deformation by compression:is this a new global stent failure,a specific failure of a particular stent design or simply an angiographic detection of an exceptional PCI complication. EuroIntervention . 2012
  • 9Bartorelli AL,Andreini D,Pontone G,Trabattoni D,Ferrari C,Mushtaq S,Ormiston JA.Stent longitudinal distortion:strut separation (pseudo-fracture)and strut compression ("concertina"effect). EuroIntervention . 2012

同被引文献2

  • 1Mamas Mamas A,Williams Paul D.Longitudinal stent deformation: insights on mechanisms, treatments and outcomes from the Food and Drug Administration Manufacturer and User Facility Device Experience database[].EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.2012
  • 2Aminian Adel,Lalmand Jacques.Major longitudinal deformation of a new-generation drug-eluting stent during withdrawal into the guide catheter[].The Journal of invasive cardiology.2012

引证文献1