摘要 BACKGROUND: The indocyanine green (ICG) retention test is the most popular liver function test for selecting patients for major hepatectomy. Traditionally, it is done using spectrophotometry with serial blood sampling. The newly- developed pulse spectrophotometry is a faster alternative, but its accuracy on Child-Pugh A cirrhotic patients undergoing hepatectomy for hepatocellular carcinoma has not been well documented. This study aimed to assess the accuracy of the LiMON , one of the pulse spectrophotometry systems, in measuring preoperative ICG retention in these patients and to devise an easy formula for conversion of the results so that they can be compared with classical literature records where ICG retention was measured by the traditional method. METHODS: We measured the liver function of 70 Child-Pugh A cirrhotic patients before hepatectomy for hepatocellular carcinoma from September 2008 to January 2009. ICG retention at 15 minutes measured by traditional spectrophotometry (ICGR15) was compared with ICG retention at 15 minutes measured by the LiMON (ICGR15(L)). RESULTS: The median ICGR15 was 14.7% (5.6%-32%) and the median ICGR15(L) was 10.4% (1.2%-28%). The mean difference between them was -4.3606. There was a strong correlation between ICGR15 and ICGR15(L) (correlation coefficient, 0.844; 95% confidence interval, 0.762-0.899). The following formula was devised: ICGR15=1.16×ICGR15(L)+2.73.CONCLUSIONS: The LiMON provides a fast and repeatable way to measure ICG retention at 15 minutes, but with constant underestimation of the real value. Therefore, when comparing results obtained by traditional spectrophotometry and the LiMON, adjustment of results from the latter is necessary, and this can be done with a simple mathematical calculation using the above formula. BACKGROUND: The indocyanine green (ICG) retention test is the most popular liver function test for selecting patients for major hepatectomy. Traditionally, it is done using spectrophotometry with serial blood sampling. The newly- developed pulse spectrophotometry is a faster alternative, but its accuracy on Child-Pugh A cirrhotic patients undergoing hepatectomy for hepatocellular carcinoma has not been well documented. This study aimed to assess the accuracy of the LiMON , one of the pulse spectrophotometry systems, in measuring preoperative ICG retention in these patients and to devise an easy formula for conversion of the results so that they can be compared with classical literature records where ICG retention was measured by the traditional method. METHODS: We measured the liver function of 70 Child-Pugh A cirrhotic patients before hepatectomy for hepatocellular carcinoma from September 2008 to January 2009. ICG retention at 15 minutes measured by traditional spectrophotometry (ICGR15) was compared with ICG retention at 15 minutes measured by the LiMON (ICGR15(L)). RESULTS: The median ICGR15 was 14.7% (5.6%-32%) and the median ICGR15(L) was 10.4% (1.2%-28%). The mean difference between them was -4.3606. There was a strong correlation between ICGR15 and ICGR15(L) (correlation coefficient, 0.844; 95% confidence interval, 0.762-0.899). The following formula was devised: ICGR15=1.16×ICGR15(L)+2.73.CONCLUSIONS: The LiMON provides a fast and repeatable way to measure ICG retention at 15 minutes, but with constant underestimation of the real value. Therefore, when comparing results obtained by traditional spectrophotometry and the LiMON, adjustment of results from the latter is necessary, and this can be done with a simple mathematical calculation using the above formula.
出处 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2012年第3期267-271,共5页 国际肝胆胰疾病杂志(英文版)
关键词 Child-Pugh A liver cirrhosis hepatocellular carcinoma indocyanine green clearance LiMON pulse spectrophotometry Child-Pugh A liver cirrhosis hepatocellular carcinoma indocyanine green clearance LiMON pulse spectrophotometry
  • 相关文献

参考文献21

  • 1Sheung Tat Fan.Liver functional reserve estimation: state of the art and relevance for local treatments[J]. Journal of Hepato - Biliary - Pancreatic Sciences . 2010 (4)
  • 2Sakka SG,Reinhart K,Wegscheider K,Meier-Hellmann A.Comparison of cardiac output and circulatory blood volumes by transpulmonary thermo-dye dilution and transcutaneous indocyanine green measurement in critically ill patients. Chest . 2002
  • 3Fan ST.Problems of hepatectomy in cirrhosis. Hepato Gastroenterology . 1998
  • 4Makuuchi M;Takayama T;Kubota K;Kimura W,Midorikawa Y,Miyagawa S,Kawasaki S.Hepatic resection for hepatocellular carcinoma-Japanese experience,1998(Suppl 3).
  • 5Jarnagin WR,Gonen M,Fong Y,et al.Improvement in perioperative outcome after hepatic resection: analysis of 1,803 consecutive cases over the past decade. Annals of Surgery . 2002
  • 6Lau H,Man K,Fan ST,et al.Evaluation of preoperative hepatic function in patients with hepatocellular carcinoma undergoing hepatectomy. British Journal of Surgery . 1997
  • 7Fan ST,Lo CM,Liu CL,et al.Hepatectomy for hepatocellular carcinoma: toward zero hospital death. Annals of Surgery . 1999
  • 8Sakka S G,Klein M,Reinhart K,et al.Prognostic value of extravascular lung water in critically ill patients. Chest . 2002
  • 9Fan ST.Methods and related drawbacks in the estimation of surgical risks in cirrhotic patients undergoing hepatectomy. Hepato Gastroenterology . 2002
  • 10W akabayashi H,Ishimura K,Izuishi K,Karasawa Y,Maeta H.Evaluation of liver function for hepatic resection for hepatocellular carcinoma in the liver with damaged parenchyma. Journal of Surgical Research . 2004

共引文献15

同被引文献37

引证文献8

二级引证文献62

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部