期刊文献+

Fine needle aspirating and cutting is superior to Tru-cut core needle in liver biopsy 被引量:2

Fine needle aspirating and cutting is superior to Tru-cut core needle in liver biopsy
下载PDF
导出
摘要 BACKGROUND:Liver biopsy is the "gold standard" for evaluating liver disorders,but controversies over the potential risk of complications and patient discomfort still exist.Using a 21G fine needle,we developed a new biopsy procedure,fine needle aspirating and cutting(FNAC).Our procedure obtains enough tissue for pathological examination and meanwhile,reduces the risk of biopsy complications.The present study was to determine the safety and efficiency of 21G FNAC compared with 18G Tru-cut core needle(TCN) in liver tumor biopsies.METHODS:Ninety-four patients with unresectable malignant tumors were included in this study.Patients were divided into 2 groups:18G TCN and 21G FNAC.The total positive rate(TPR) and safety of both groups were compared.RESULTS:TPR was not different between the two groups.Liver puncture track subcapsular hemorrhage and arteriovenous shunt were reported with 18G TCN but not with 21G FNAC.The incidence of pain caused by biopsy was higher for the 18G TCN group compared to the 21G FNAC group(P【0.05).About 82.6% of the patients in the 18G TCN group had a sample length 】0.5 cm,but 52.1% in the 21G FNAC group(P【0.05).More than 50% of patients in both groups had sufficient tissue for immunohistochemical examination.CONCLUSIONS:TPR is not different between the 21G FNAC and 18G TCN biopsy procedures,but the safety of 21G FNAC is superior to that of 18G TCN.Tissues obtained by either of these two procedures are sufficient for a pathological diagnosis. BACKGROUND:Liver biopsy is the "gold standard" for evaluating liver disorders,but controversies over the potential risk of complications and patient discomfort still exist.Using a 21G fine needle,we developed a new biopsy procedure,fine needle aspirating and cutting(FNAC).Our procedure obtains enough tissue for pathological examination and meanwhile,reduces the risk of biopsy complications.The present study was to determine the safety and efficiency of 21G FNAC compared with 18G Tru-cut core needle(TCN) in liver tumor biopsies.METHODS:Ninety-four patients with unresectable malignant tumors were included in this study.Patients were divided into 2 groups:18G TCN and 21G FNAC.The total positive rate(TPR) and safety of both groups were compared.RESULTS:TPR was not different between the two groups.Liver puncture track subcapsular hemorrhage and arteriovenous shunt were reported with 18G TCN but not with 21G FNAC.The incidence of pain caused by biopsy was higher for the 18G TCN group compared to the 21G FNAC group(P<0.05).About 82.6% of the patients in the 18G TCN group had a sample length >0.5 cm,but 52.1% in the 21G FNAC group(P<0.05).More than 50% of patients in both groups had sufficient tissue for immunohistochemical examination.CONCLUSIONS:TPR is not different between the 21G FNAC and 18G TCN biopsy procedures,but the safety of 21G FNAC is superior to that of 18G TCN.Tissues obtained by either of these two procedures are sufficient for a pathological diagnosis.
出处 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2013年第5期508-511,共4页 国际肝胆胰疾病杂志(英文版)
基金 supported by a grant from the Project of Shanghai Health Bureau(2010022)
关键词 BIOPSY tumor CHEMOEMBOLIZATION diagnostic liver biopsy tumor chemoembolization diagnostic liver
  • 相关文献

参考文献23

  • 1Joe West,Timothy R. Card.Reduced Mortality Rates Following Elective Percutaneous Liver Biopsies[J]. Gastroenterology . 2010 (4)
  • 2D.Van Der Poorten,A.Kwok,T.Lam,L.Ridley,D. B.Jones,M. C.Ngu,A. U.Lee.Twenty‐year audit of percutaneous liver biopsy in a major Australian teaching hospital[J]. Internal Medicine Journal . 2006 (11)
  • 3E.S. Bialecki.Comparison of Liver Biopsy and Noninvasive Methods for Diagnosis of Hepatocellular Carcinoma[J]. Clinical Gastroenterology and Hepatology . 2006 (3)
  • 4Z. Amin,B. Theis,R.C.G. Russell,C. House,M. Novelli,W.R. Lees.Diagnosing pancreatic cancer: the role of percutaneous biopsy and CT[J]. Clinical Radiology . 2006 (12)
  • 5Loukas Thanos,Alexandra Zormpala,Georgia Papaioannou,Katerina Malagari,Elias Brountzos,Dimitrios Kelekis.Safety and efficacy of percutaneous CT-guided liver biopsy using an 18-gauge automated needle[J]. European Journal of Internal Medicine . 2005 (8)
  • 6Ahmed Own,Joern O. Balzer,Thomas J. Vogl.Bleeding hepatic pseudoaneurysm complicating percutaneous liver biopsy with interventional treatment options[J]. European Radiology . 2005 (1)
  • 7James L. Swischuk,Flavio Castaneda,Jitendra C. Patel,Ruizong Li,Kenneth W. Fraser,Terrence M. Brady,Raymond E. Bertino.Percutaneous Transthoracic Needle Biopsy of the Lung: Review of 612 Lesions[J]. Journal of Vascular and Interventional Radiology . 1998 (2)
  • 8Zobair M. Younossi,J. Carlos Teran,Theodore G. Ganiats,William D. Carey.Ultrasound-Guided Liver Biopsy for Parenchymal Liver Disease (An Economic Analysis)[J]. Digestive Diseases and Sciences . 1998 (1)
  • 9KD Lindor,C Bru,RA Jorgensen,J Rakela,JM Bordas,JB Gross,J Rodes,DB McGill,CC Reading,EM James,JW Charboneau,J Ludwig,KP Batts,AR Zinsmeister.The role of ultrasonography and automatic-needle biopsy in outpatient percutaneous liver biopsy[J]. Hepatology . 1996 (5)
  • 10Dr. F. Froehlich MD,O. Lamy MD,M. Fried MD,J. J. Gonvers MD.Practice and complications of liver biopsy[J]. Digestive Diseases and Sciences . 1993 (8)