摘要 AIM:To investigate the effects of a new opening pattern in neodymium:yttrium-aluminum-garnet(Nd:YAG)laser posterior capsulotomy on visual function.METHODS:This technique was conducted along a circular pattern.The energy ranged between 0.8 and1.2 mJ/pulse was consumed and mean total energy levels were 74±21 mJ(mean±standard deviation:SD,from 40 to167)and laser shots aimed at 150μm away behind a datum point and went along an imaginary line which extends 0.5 mm inside from optic margin and into the circular en bloc pattern.Vitreous stands were attached with fragment and then they were cut off by the laser after circular application.The circular fragment was completely separated from vitreous,and then this fragment was quickly sunk in intravitreal space.RESULTS:The follow-up period ranges from at least a week to 40mo,making 15.8mo on average.The procedural outcome showed 96%(74 eyes out of the 77eyes)enhancement in patients'visual acuity.Cystoid macular edema or retinal detachment was not observed in any of the patients during follow-up periods.CONCLUSION:This new technique is expected to improve the weaknesses that the conventional procedures have by adding the process to cut off vitreous stands attached with the fragment by the laser to the circular application. AIM:To investigate the effects of a new opening pattern in neodymium:yttrium-aluminum-garnet(Nd:YAG)laser posterior capsulotomy on visual function.METHODS:This technique was conducted along a circular pattern.The energy ranged between 0.8 and1.2 mJ/pulse was consumed and mean total energy levels were 74±21 mJ(mean±standard deviation:SD,from 40 to167)and laser shots aimed at 150μm away behind a datum point and went along an imaginary line which extends 0.5 mm inside from optic margin and into the circular en bloc pattern.Vitreous stands were attached with fragment and then they were cut off by the laser after circular application.The circular fragment was completely separated from vitreous,and then this fragment was quickly sunk in intravitreal space.RESULTS:The follow-up period ranges from at least a week to 40mo,making 15.8mo on average.The procedural outcome showed 96%(74 eyes out of the 77eyes)enhancement in patients’visual acuity.Cystoid macular edema or retinal detachment was not observed in any of the patients during follow-up periods.CONCLUSION:This new technique is expected to improve the weaknesses that the conventional procedures have by adding the process to cut off vitreous stands attached with the fragment by the laser to the circular application.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期345-349,共5页 国际眼科杂志(英文版)
关键词 CATARACT INTRAOCULAR lens damage posterior CAPSULAR OPACIFICATION VITREOUS strand YAG laser CAPSULOTOMY cataract, intraocular lens damage, posterior capsular opacification, vitreous strand, YAG laser capsulotomy
  • 相关文献

同被引文献12

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部