期刊文献+

Comparative study of visual acuity and aberrations after intralase femtosecond LASIK:small corneal flap versus big corneal flap 被引量:4

Comparative study of visual acuity and aberrations after intralase femtosecond LASIK:small corneal flap versus big corneal flap
下载PDF
导出
摘要 AIM:To study the effects of different flap sizes on visual acuity,refractive outcomes,and aberrations after femtosecond laser for laser in situ keratomileusis(LASIK).METHODS:In each of the forty patients enrolled,1 eye was randomly assigned to receive treatment with a 8.1mm diameter corneal flap,defined as the small flap,while the other eye was treated with a 8.6mm diameter corneal flap,defined as the big flap.Refractive errors,visual acuity,and higher-order aberrations were compared between the two groups at week 1,month 1 and 3 postoperatively. RESULTS:The postoperative refractive errors and visual acuity all conformed to the intended goal.Postoperative higher-order aberrations were increased,especially in spherical aberration(Z12) and vertical coma(Z7).There were no statistically significant differences between the two groups in terms of postoperative refractive errors,visual acuity,root mean square of total HOAs(HO-RMS),trefoil 30°(Z6),vertical coma(Z7),horizontal coma(Z8),trefoil 0°(Z9),and spherical aberration(Z12) at any point during the postoperative follow-up.CONCLUSION:Both the small and big flaps are safe and effective procedures to correct myopia,provided the exposure stroma meets the excimer laser ablations.The personalized size corneal flap is feasible,as we can design the size of corneal flap based on the principle that the corneal flap diameter should be equal to or greater than the sum of the maximum ablation diameter and apparatus error. AIM:To study the effects of different flap sizes on visual acuity,refractive outcomes,and aberrations after femtosecond laser for laser in situ keratomileusis(LASIK).METHODS:In each of the forty patients enrolled,1 eye was randomly assigned to receive treatment with a 8.1mm diameter corneal flap,defined as the small flap,while the other eye was treated with a 8.6mm diameter corneal flap,defined as the big flap.Refractive errors,visual acuity,and higher-order aberrations were compared between the two groups at week 1,month 1 and 3 postoperatively. RESULTS:The postoperative refractive errors and visual acuity all conformed to the intended goal.Postoperative higher-order aberrations were increased,especially in spherical aberration(Z12) and vertical coma(Z7).There were no statistically significant differences between the two groups in terms of postoperative refractive errors,visual acuity,root mean square of total HOAs(HO-RMS),trefoil 30°(Z6),vertical coma(Z7),horizontal coma(Z8),trefoil 0°(Z9),and spherical aberration(Z12) at any point during the postoperative follow-up.CONCLUSION:Both the small and big flaps are safe and effective procedures to correct myopia,provided the exposure stroma meets the excimer laser ablations.The personalized size corneal flap is feasible,as we can design the size of corneal flap based on the principle that the corneal flap diameter should be equal to or greater than the sum of the maximum ablation diameter and apparatus error.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期641-645,共5页 国际眼科杂志(英文版)
关键词 femtosecond laser laser in situ keratomileusis refractive surgery FLAP visual acuity ABERRATION femtosecond laser laser in situ keratomileusis refractive surgery flap visual acuity aberration
  • 相关文献

参考文献20

  • 1Eleftherios I. Paschalis,Georgios Labiris,Antonis P. Aristeidou,Nikitas C. Foudoulakis,Stavrenia C. Koukoula,Vassilios P. Kozobolis.Laser in situ keratomileusis flap-thickness predictability with a pendular microkeratome[J]. Journal of Cataract & Refractive Surgery . 2011 (12)
  • 2Ammar Issa,Usama Al Hassany.Femtosecond laser flap parameters and visual outcomes in laser in situ keratomileusis[J]. Journal of Cataract & Refractive Surgery . 2011 (4)
  • 3Shanshan Du,Jingcai Lian,Lei Zhang,Sheng Ye,Shiqi Dong.Flap thickness variation with 3 types of microkeratome heads[J]. Journal of Cataract & Refractive Surgery . 2011 (1)
  • 4F.-X. Kouassi,M. Blaizeau,C. Buestel,C. Schweitzer,A. Gallois,J. Colin,D. Touboul.Comparaison entre le Lasik au laser femtoseconde et le Lasik au microkératome mécanique : prédictibilité des découpes, biomécanique cornéenne et aberrations optiques[J]. Journal Francais d’Ophtalmologie . 2011 (1)
  • 5Alok S. Bansal,Terrence Doherty,J. Bradley Randleman,R. Doyle Stulting.Influence of flap thickness on visual and refractive outcomes after laser in situ keratomileusis performed with a mechanical keratome[J]. Journal of Cataract & Refractive Surgery . 2010 (5)
  • 6William J. Dupps,Steven E. Wilson.Biomechanics and wound healing in the cornea[J]. Experimental Eye Research . 2006 (4)
  • 7Taehyung Lim,Sungjae Yang,Myoungjoon Kim,Hungwon Tchah.Comparison of the IntraLase Femtosecond Laser and Mechanical Microkeratome for Laser In Situ Keratomileusis[J]. American Journal of Ophthalmology . 2006 (5)
  • 8Perry S Binder.Flap dimensions created with the IntraLase FS laser[J]. Journal of Cataract & Refractive Surgery . 2004 (1)
  • 9Alexander Heisterkamp,Thanongsak Mamom,Omid Kermani,Wolfgang Drommer,Herbert Welling,Wolfgang Ertmer,Holger Lubatschowski.Intrastromal refractive surgery with ultrashort laser pulses: in vivo study on the rabbit eye[J]. Graefe’s Archive for Clinical and Experimental Ophthalmology . 2003 (6)
  • 10Alan Sugar,Christopher J Rapuano,William W Culbertson,David Huang,Gary A Varley,Peter J Agapitos,Vincent P de Luise,Douglas D Koch.Laser in situ keratomileusis for myopia and astigmatism: safety and efficacy[J]. Ophthalmology . 2002 (1)

共引文献2

同被引文献8

引证文献4

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部