摘要 AIM:To evaluate the clinical outcomes after Ferrara intrastromal corneal ring segments(ICRS)reoperation in patients with keratoconus.METHODS:A total of 37 keratoconus eyes implanted with intrastromal corneal ring segments,which had an ICRS exchange,addition,reposition or removal were evaluated.Uncorrected visual acuity(UCVA),best corrected visual acuity(BCVA),keratometry(K),asphericity(Q)and pachymetry at the thinnest point(PTP)of the cornea were evaluated using a corneal tomography(Oculus Pentacam,USA)RESULTS:The mean follow-up time after the reoperation was 30.5±9.7 months.The mean UCVA improved from 20/300 to 20/80(P=0.005);the mean BCVA improved from 20/160 to 20/50(P=0.0002),the mean keratometry reduced from 49.33±4.19D to 46.16±3.90D(P=0.0001),the mean pachymetry at the thinnest point increased from 450±42.9μm to 469±40.8μm(P=0.0001).The asphericity increased from-0.84±0.74 to-0.35±0.81(P=0.15)and the spherical equivalent reduced from-4.64±4.87D to-3.04±3.45D(P=0.137).The changes in the asphericity and spherical equivalent were not statistically significant.CONCLUSION:Ferrara ICRS implantation showed to be a reversible and readjustable surgical procedure for keratoconus treatment.Good outcomes can be obtained even after removal,addition,reposition or exchange of ICRS. AIM:To evaluate the clinical outcomes after Ferrara intrastromal corneal ring segments(ICRS)reoperation in patients with keratoconus.METHODS:A total of 37 keratoconus eyes implanted with intrastromal corneal ring segments,which had an ICRS exchange,addition,reposition or removal were evaluated.Uncorrected visual acuity(UCVA),best corrected visual acuity(BCVA),keratometry(K),asphericity(Q)and pachymetry at the thinnest point(PTP)of the cornea were evaluated using a corneal tomography(Oculus Pentacam,USA)RESULTS:The mean follow-up time after the reoperation was 30.5±9.7 months.The mean UCVA improved from 20/300 to 20/80(P=0.005);the mean BCVA improved from 20/160 to 20/50(P=0.0002),the mean keratometry reduced from 49.33±4.19D to 46.16±3.90D(P=0.0001),the mean pachymetry at the thinnest point increased from 450±42.9μm to 469±40.8μm(P=0.0001).The asphericity increased from-0.84±0.74 to-0.35±0.81(P=0.15)and the spherical equivalent reduced from-4.64±4.87D to-3.04±3.45D(P=0.137).The changes in the asphericity and spherical equivalent were not statistically significant.CONCLUSION:Ferrara ICRS implantation showed to be a reversible and readjustable surgical procedure for keratoconus treatment.Good outcomes can be obtained even after removal,addition,reposition or exchange of ICRS.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第6期796-800,共5页 国际眼科杂志(英文版)
关键词 KERATOCONUS intrastromal corneal ring segments REOPERATION keratoconus, intrastromal corneal ring segments, reoperation
  • 相关文献

参考文献24

  • 1Zeki Tunc,Firat Helvacioglu,Sadik Sencan.Evaluation of intrastromal corneal ring segments for treatment of keratoconus with a mechanical implantation technique[J]. Indian Journal of Ophthalmology . 2013 (5)
  • 2Guilherme Ferrara,Leonardo Torquetti,Paulo Ferrara,Jesús Merayo‐Lloves.Intrastromal corneal ring segments: visual outcomes from a large case series[J]. Clinical & Experimental Ophthalmology . 2012 (5)
  • 3Almutez M Gharaibeh,Sana? M Muhsen,Ilham B AbuKhader,Osama H Ababneh,Mohammed A Abu-Ameerh,Muawyah D Albdour.KeraRing Intrastromal Corneal Ring Segments for Correction of Keratoconus[J]. Cornea . 2012 (2)
  • 4Tatiana Moura Bastos Prazeres,Allan Cezar da Luz Souza,Nicolas Cesário Pereira,Fábio Ursulino,Leon Grupenmacher,Luciene Barbosa de Souza.Intrastromal Corneal Ring Segment Implantation by Femtosecond Laser for the Correction of Residual Astigmatism After Penetrating Keratoplasty[J]. Cornea . 2011 (12)
  • 5Anil Kubaloglu,Esin Sogutlu Sari,Yasin Cinar,Kür?at Cingu,Arif Koytak,Erol Co?kun,Yusuf ?zertürk.Comparison of mechanical and femtosecond laser tunnel creation for intrastromal corneal ring segment implantation in keratoconus[J]. Journal of Cataract & Refractive Surgery . 2010 (9)
  • 6José L. Güell,Merce Morral,Cecilia Salinas,Daniel Elies,Oscar Gris,Felicidad Manero.Intrastromal corneal ring segments to correct low myopia in eyes with irregular or abnormal topography including forme fruste keratoconus: 4-year follow-up[J]. Journal of Cataract & Refractive Surgery . 2010 (7)
  • 7Bruno M. Fontes,Renato Ambrósio,Daniela Jardim,Guillermo C. Velarde,Walton Nosé.Corneal Biomechanical Metrics and Anterior Segment Parameters in Mild Keratoconus[J]. Ophthalmology . 2010 (4)
  • 8David PPi?ero,Jorge LAlio.Intracorneal ring segments in ectatic corneal disease – a review[J]. Clinical & Experimental Ophthalmology . 2010 (2)
  • 9Leonardo Torquetti,Rodrigo Fabri Berbel,Paulo Ferrara.Long-term follow-up of intrastromal corneal ring segments in keratoconus[J]. Journal of Cataract & Refractive Surgery . 2009 (10)
  • 10Caroline Dauwe,David Touboul,Cynthia J. Roberts,Ashraf M. Mahmoud,Julien Kérautret,Pierre Fournier,Fran?ois Malecaze,Joseph Colin.Biomechanical and morphological corneal response to placement of intrastromal corneal ring segments for keratoconus[J]. Journal of Cataract & Refractive Surgery . 2009 (10)