期刊文献+

Blue-on-yellow perimetry and corneal thickness in patients with ocular hypertension

Blue-on-yellow perimetry and corneal thickness in patients with ocular hypertension
下载PDF
导出
摘要 AIM: To evaluate the frequency of blue-on-yellow perimetry (B/YP) deficits in ocular hypertension (OHT) patients and to correlate these findings with central corneal thickness (CCT), and to investigate the influence of age, refraction and gender on the B/YP results in OHT patients. METHODS: The B/YP and CCT were checked respectively in 72 OHT patients with normal white-on-white perimetry (W/WP) and normal optic nerve head. The B/YP was tested by Octopus 101 automated perimetry using G2 strategy, while the CCT was checked with DGH-550 ultrasound pachymeter. All patients were chosen randomly one eye for statistical analysis, a binary regression model was used to determine the independent contribution of variables included in the model, and the differences of the intraocular pressure (TOP), CCT, age, refraction and gender between the normal B/YP group and abnormal B/YP group were compared. RESULTS: Forty-nine out of 72 patients with OHT showed normal B/YP results, whereas 23 of 72 patients (31.9%) demonstrated abnormal B/YP results. CCT showed a correlation with the B/YP results (B=-0.038, SE=0.019, P=0.044), whereas none of the TOP, age, refraction and gender was found to be correlated with the B/YP results. The mean CCT in OHT patients with abnormal B/YP group was lower than that with normal B/YP group (t=2.066, P=0.043). There was a significant positive correlation between TOP and CCT (R(2)=0.513, P=0.000). CONCLUSION: The mean CCT in OHT patients with abnormal B/YP results was lower than that with normal B/YP results. There was a significant positive correlation between TOP and CCT in OHT patients. The age, refraction and gender didn't influence the B/YP results in OHT patients. AIM: To evaluate the frequency of blue-on-yellow perimetry (B/YP) deficits in ocular hypertension (OHT) patients and to correlate these findings with central corneal thickness (CCT), and to investigate the influence of age, refraction and gender on the B/YP results in OHT patients. METHODS: The B/YP and CCT were checked respectively in 72 OHT patients with normal white-on-white perimetry (W/WP) and normal optic nerve head. The B/YP was tested by Octopus 101 automated perimetry using G2 strategy, while the CCT was checked with DGH-550 ultrasound pachymeter. All patients were chosen randomly one eye for statistical analysis, a binary regression model was used to determine the independent contribution of variables included in the model, and the differences of the intraocular pressure (TOP), CCT, age, refraction and gender between the normal B/YP group and abnormal B/YP group were compared. RESULTS: Forty-nine out of 72 patients with OHT showed normal B/YP results, whereas 23 of 72 patients (31.9%) demonstrated abnormal B/YP results. CCT showed a correlation with the B/YP results (B=-0.038, SE=0.019, P=0.044), whereas none of the TOP, age, refraction and gender was found to be correlated with the B/YP results. The mean CCT in OHT patients with abnormal B/YP group was lower than that with normal B/YP group (t=2.066, P=0.043). There was a significant positive correlation between TOP and CCT (R(2)=0.513, P=0.000). CONCLUSION: The mean CCT in OHT patients with abnormal B/YP results was lower than that with normal B/YP results. There was a significant positive correlation between TOP and CCT in OHT patients. The age, refraction and gender didn't influence the B/YP results in OHT patients.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2011年第6期623-626,共4页 国际眼科杂志(英文版)
基金 Supported by Shanghai Leading Academi Discipline Project, China (No.S30205) Shanghai Municipal Health Bureau Project, China(No.034075)
关键词 ocular hypertension blue-on-yellow perimetry central corneal thickness visual function ocular hypertension blue-on-yellow perimetry central corneal thickness visual function
  • 相关文献

参考文献22

  • 1Brusini P,Tosoni C,Parisi L,Rizzi L.Ocular hypertension and corneal thickness: a long- term prospective study. Results after two years. European Journal of Ophthalmology . 2005
  • 2Dadaci Z,Bozkurt B,Irke MT,Orhan M,Arslan U.Relationship between short wavelength perimetry and central corneal thickness values in ocular hypertensive subjects. European Journal of Ophthalmology . 2006
  • 3Doughty MJ,Laiquzzaman M,Müller A,Oblak E,Button NF.Central corneal thickness in European (white) individuals, especially children and the elderly, and assessment of its possible importance in clinical measures of intra- ocular pressure. Ophthalmic and Physiological Optics . 2002
  • 4Wall M.What’’’’s newin perimetry. Journal of Neuro Ophthalmology . 2004
  • 5Vass C.Modern diagnostic methods for suspected glaucoma and glaucoma. Klinische Monatsblatter fur Augenheilkunde . 2004
  • 6Lee GA,Khaw PT,Ficker LA,et al.The corneal thickness and intraocular pressure story:where are we now?. Clinical and Experimental . 2002
  • 7Kass MA,Heuer DK,Higginbotham EJ,et al.The ocular hypertension treatment study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma. Archives of Ophthalmology . 2002
  • 8Quigley HA;Dunkelberger GR;Green WA.Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma,1989.
  • 9Shah S,Chatterjee A,Mathai M,et al.Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic. Ophthalmology . 1999
  • 10Polo V,Larrosa JM,Pinilla I,PerezS,Gonzalvo F,H onrubia FM.Predic-tive value of short-wavelength autom ated perim etry:a3-year follow-up study. Ophthalmology . 2002

共引文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部