期刊文献+

Penumbral imaging and numerical evaluation of large area source neutron imaging system 被引量:3

Penumbral imaging and numerical evaluation of large area source neutron imaging system
原文传递
导出
摘要 The fusion neutron penumbral imaging system Monte Carlo model was established. The transfer functions of the two discrete units in the neutron source were obtained in two situations: Imaging in geometrical near-optical and real situation. The spatial resolutions of the imaging system in two situations were evaluated and compared. The penumbral images of four units in the source were obtained by means of 2-dimensional (2D) convolution and Monte Carlo simulation. The penumbral images were reconstructed with the same method of filter. The same results were confirmed. The encoding essence of penumbral imaging was revealed. With MCNP(Monte Carlo N-particle) simulation, the neutron penumbral images of the large area source (200 μm×200 μm) on scintillation fiber array were obtained. The improved Wiener filter method was used to reconstruct the penumbral image and the source image was obtained. The results agree with the preset neutron source image. The feasibility of the neutron imaging system was verified.
出处 《Science China(Technological Sciences)》 SCIE EI CAS 2009年第9期2567-2575,共9页 中国科学(技术科学英文版)
基金 Supported by the NSAF Joint Fund set up by NSFC and CAEP (Grant No. 10576022)
关键词 penumbral imaging reconstruction unit SOURCE SPATIAL INVARIANCE SPATIAL RESOLUTION MCNP code penumbral imaging reconstruction unit source spatial invariance spatial resolution MCNP code
  • 相关文献

参考文献16

  • 1Mosinski G,Roy B.CEA Bruyeres le Chatel, Diagnostic Develop-ment at LLNL for National Ignition Facility. Report No. 79/DR 83. Department of Energy’s National Nuclear Security Ad- ministration in the US . 1983
  • 2Sommargren G E,Lerche R A.Neutron Imaging of ICF Target Plasmas. Report No. CA, UCID-19317Lawrence Liv- ermore National Laboratory . 1988
  • 3Rouyer A. The Review of Scientific Instruments . 2003
  • 4Chen F X,Yang J L,Wen S H.ICF neutron pinhole imaging numerical simulation (in Chinese). Laser and Particle Beams . 2005
  • 5Liu D J,Tang X H,Zhao Z Q, et al.Neutron imaging penumbral image inversion method. Laser and Particle Beams . 2006
  • 6Fa-Xin Chen,Zheng,Jian-Lun Yang.Thick neutron pinhole imaging numerical simulation. Acta Physiologica Sinica . 2006
  • 7Ress D.Neutron imaging for inertial-confinement-fusion experiment. IEEE Transactions on Nuclear Science . 1996
  • 8Wu Y L,Hu H S.Crosstalk and Time Response of a Plastic Scintilla-tion Optical Fibers Array for Neutron Imaging. Proceedings of the 16th International Conference on Nuclear Engineering . 2008
  • 9Hu H S,Wang Q S,Juan Q, et al.Study on composite material for shielding mixed neutron and γ-rays. IEEE Transactions on Nuclear Science . 2008
  • 10Gillman G,Macleod I.Reconstruction of X-ray sources form pen-umbral images. Comput Graphic Image Process . 1979

同被引文献24

  • 1ZHAO ChuanZhen, XIU XiangQian , ZHANG Rong , XIE ZiLi, LIU Bin, LIU ZhanHui, YAN HuaiYue & ZHENG YouDou Jiangsu Provincial Key Laboratory of Advanced Photonic and Electronic Materials, Department of Physics, Nanjing University, Nanjing 210093, China.Simulation of growing GaN in vertical HVPE reactor[J].Science China(Physics,Mechanics & Astronomy),2010,53(1):72-75. 被引量:3
  • 2ShuHuan Liu,XinBiao Jiang,YunHong Zhong,QingYu Yu,WenShou Zhang,Kai Wang,Jun Yang,YingLin Wang.Parameters measurement for the thermal neutron beam in the thermal column hole of Xi'an pulse reactor[J].Science China(Technological Sciences),2010,53(5):1220-1224. 被引量:2
  • 3Cathy J. Ridgway,Patrick A. C. Gane,Abd El-Ghany El Abd,Andrzej Czachor.Water Absorption into Construction Materials: Comparison of Neutron Radiography Data with Network Absorption Models[J]. Transport in Porous Media . 2006 (3)
  • 4H. Pleinert,H. Sadouki,F. H. Wittmann.Determination of moisture distributions in porous building materials by neutron transmission analysis[J]. Materials and Structures . 1998 (4)
  • 5Phillipson M C,,Baker P H,Davies M,et al.Moisture measurement in building materials:an overview of current methods and new ap-proaches. Build Serv Eng Res Technol . 2007
  • 6Roels S,Carmeliet J,Hens H,et al.A comparison of different tech-niques to quantify moisture content profiles in porous building mate-rials. J Therm Envelope Build Sci . 2004
  • 7Prazak J,Lunp P.Capillary suction of autoclaved aerated concrete. Advances in Autoclaved Aerated Concrete . 1992
  • 8Masschaele B,Dierick M,Cnudde V,et al.High-speed thermal neu-tron tomography for the visualization of water repellents,consoli-dants and water uptake in sand and lime stones. Radiation Physics and Chemistry . 2004
  • 9Pugliesi R,Andrade M L G.Study of cracking in concrete by neutron radiography. Applied Radiation and Isotopes . 1997
  • 10Zhang Peng,Wittmann F H,Zhao T J,et al.Observation of water penetration into water repellent and cracked cement-based materials by means of neutron radiography. Int J Restor Build Monum . 2009

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部