期刊文献+

Numerical simulation of a thermal-bubble actuated diffuser-nozzle valveless pump 被引量:1

Numerical simulation of a thermal-bubble actuated diffuser-nozzle valveless pump
原文传递
导出
摘要 A valveless micropump actuated by thermal bubbles which are generated by an electrode heater mounted with a pair of diffuser nozzles has been numerically studied by commercial CFD software FLUENT. The relationships between the net flow rate and the superheating and heat supplying frequency have been investigated. The depth of the diffuser-nozzle micropump is 200 μm, the diameter of the actuating chamber is 1 mm, and a pair of diffuser nozzles whose gap has been expanded from 30 μm to 274 μm with an open angle of 7° are connected to the actuating chamber. The working fluid is methanol. In the numerical simulation, the flow pattern is laminar. The results show that the pump has different optimal driving frequencies at different superheating. A cycle resulting from bubble growth and shrinking costs more time at higher superheating temperature; different superheating has different optimal driving frequency; when the superheating increases, the maximum volume flow rate and the maximum pump pressure will increase simultaneously, and the optimal driving frequency decreases as well, the maximum volume flow rate and pump pressure also have the same tendency; in the condition of uncontrolled condensing, the bubble shrinking process is longer than the growth process, thus it is the determining factor to affect the pump performance. The maximum volume flow rate is 9.02 μL/min at △T = 15℃, and the maximum pump pressure is 680 Pa. With the increase of wall superheat, cycle including the bubble growth and condensation will become longer, resulting in a significant impact on the pumping flow; different wall superheat has different optimized frequency, increasing superheat will bring increased pumping flow and pump pressure, the optimized driving frequency will be reduced; liquid supply phase is longer than pumping phase. A valveless micropump actuated by thermal bubbles which are generated by an electrode heater mounted with a pair of diffuser nozzles has been numerically studied by commercial CFD software FLUENT. The relationships between the net flow rate and the superheating and heat supplying frequency have been investigated. The depth of the diffuser-nozzle micropump is 200 μm, the diameter of the actuating chamber is 1 mm, and a pair of diffuser nozzles whose gap has been expanded from 30 μm to 274 μm with an open angle of 7° are connected to the actuating chamber. The working fluid is methanol. In the numerical simulation, the flow pattern is laminar. The results show that the pump has different optimal driving frequencies at different superheating. A cycle resulting from bubble growth and shrinking costs more time at higher superheating temperature; different superheating has different optimal driving frequency; when the superheating increases, the maximum volume flow rate and the maximum pump pressure will increase simultaneously, and the optimal driving frequency decreases as well, the maximum volume flow rate and pump pressure also have the same tendency; in the condition of uncontrolled condensing, the bubble shrinking process is longer than the growth process, thus it is the determining factor to affect the pump performance. The maximum volume flow rate is 9.02 μL/min at ΔT = 15°C, and the maximum pump pressure is 680 Pa. With the increase of wall superheat, cycle including the bubble growth and condensation will become longer, resulting in a significant impact on the pumping flow; different wall superheat has different optimized frequency, increasing superheat will bring increased pumping flow and pump pressure, the optimized driving frequency will be reduced; liquid supply phase is longer than pumping phase.
出处 《Science China(Technological Sciences)》 SCIE EI CAS 2009年第10期2967-2972,共6页 中国科学(技术科学英文版)
基金 Supported by the National Natural Science Foundation of China (Grant No. 50406012)
关键词 THERMAL BUBBLE actuating valveless diffuser-nozzle MICROPUMP NUMERICAL simulation thermal bubble actuating valveless diffuser-nozzle micropump numerical simulation
  • 相关文献

参考文献8

  • 1陈德奇,潘良明,袁德文,邓杰文,王小军.竖直矩形窄流道内汽泡生长的实验研究[J].核动力工程,2008,29(5):52-55. 被引量:17
  • 2Kim J,Xu X.Laser-based fabrication of polymer micropump. Soc Photo-Opt Instrum Eng . 2004
  • 3Mareka R,Straub J.Analysis of the evaporation coefficient and the condensation coefficient of water. International Journal of Heat and Mass Transfer . 2001
  • 4Olsson A,Enoksson P,Stemme G,et al.Micromachined flat-walled valveless diffuser pumps. Journal of Microbiology . 1997
  • 5Andersson H,Wijngaart W V D,Nilsson P,et al.Avalveless diffuser micropump for microfluidic analytical systems. Sensors and Actuators . 2001
  • 6Jun,T.K.,Kim,C.-J.Valveless Pumping Using Traversing Vapor Bubbles in Microchannels. Journal of Applied Physics . 1998
  • 7Tsai J H,Lin L.Athermal-bubble-actuated micronozzle-diffuser pump. Journal of Microelectromechanical Systems . 2002
  • 8Tong L S,and Tang Y S.Boiling Heat Transfer and Two-phase flow. . 1997

二级参考文献7

  • 1潘良明,陈德奇,袁德文.竖直矩形窄缝内流动沸腾压降实验与模型研究[J].工程热物理学报,2007,28(2):255-258. 被引量:6
  • 2Mehendal S S, Jacobi A M, Shah R K. Fluid Flow and Heat Transfer at Micro and Meso-Scales with Application to Heat Exchanger Design[J]. Appl Mech Rev 53 (7): 175-193.
  • 3Kandlikar S.G Two-Phase Flow Pattems, Pressure Drop, and Heat Transfer During Boiling in Minichannel Flow Passages of Compact Heat Evaporators[J], Heat Trasfer Engineering, 2002, 23(5): 5-23.
  • 4John R Thome. Review On Two-Phase Flow Instabilities in Narrow Spaces[J]. Heat and Fluid Flow, 2004, 25: 128-139.
  • 5Azbel D. Two-Phase Flow in Chemical Engineering. USA: Cambridge University Pres, 1981.
  • 6Thomcroft G E, Klausner J F, Mei R. An Experimental Investigation of Bubble Growth and Detachment In Ver- tical Upflow and Downflow Boiling [J]. Heat Mass Transfer, 1998, 41:3857-3871.
  • 7Van Helden W G J, Van Der. Geld C W M., Boot P G M. Forces On Bubble Growing and Detaching in Flow Along a Vertical Wall [J]. Heat Mass Transfer, 1995, 38 (11): 2075-2088.

共引文献16

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;