空气能热泵热水器热气除霜方案研究

The Study on Hot Gas Defrosting Method of Heat Pump Water Heater
下载PDF
导出
摘要 本文主要从能源角度对现有常规热泵热水器热气旁通除霜和热气逆向除霜进行了比较;介绍了通过采用除霜周期内最大平均制热量及最大平均能效作为热气逆向除霜进入点的新控制方案;通过与常规时间-温度控制除霜方法进行了实验对比,从实验数据对比中得出,采用平均制热量最大值法能够在一个除霜周期中提高制热量10.2%;采用最大平均能效法能够提高能效2.8%。 本文主要从能源角度对现有常规热泵热水器热气旁通除霜和热气逆向除霜进行了比较;介绍了通过采用除霜周期内最大平均制热量及最大平均能效作为热气逆向除霜进入点的新控制方案;通过与常规时间-温度控制除霜方法进行了实验对比,从实验数据对比中得出,采用平均制热量最大值法能够在一个除霜周期中提高制热量10.2%;采用最大平均能效法能够提高能效2.8%。
出处 《电器》 2012年第S1期565-570,共6页 China Appliance
关键词 热泵热水器 热气除霜 逆向除霜 最大平均制热量 最大平均能效 Heat pump water heater Hot gas defrosting Reverse-Cycle defrosting Maximum average heating capacity Maximum average Coefficient of Performance
  • 相关文献

参考文献1

二级参考文献13

  • 1O'Neal D L,Pterson K T,Anand N K.Effect of short-tube orifice size on the performance of an air source heat pump during the reverse-cycle defrost[J].Int J Refrig,1991,14(7):52-57.
  • 2Nutter D W,O'Neal D L,Payne W V.Impact of the suction line accumulator on the frost/defrost performance of an air-source heat pump with a scroll compressor[J].ASHRAE Transaction,1993,99(2):689-698.
  • 3Payne V,O'Neal D L.Defrost cycle performance for an air-source heat pump with a scroll and a reciprocating compressor [J].Int J Refrig,1995,18(2):107-112.
  • 4Krakow K I,Lin S,Yan L.Idealized model of reverse-cycle hot gas defrosting:theory [J].ASHRAE Transaction,1993,99(2):317-328.
  • 5Krakow K I,Lin S,Yan L.Idealized model of reverse-cycle hot gas defrosting:experimental analysis and validation[J].ASHRAE Transaction,1993,99(2):329-338.
  • 6Ding Yuanjun,Ma Guoyuan,Chai Qinhu,et al.Experiment investigation of reverse cycle defrosting methods on air source heat pump with TXV as the throttle regulator [J].Int J Refrig,2004,27(6):671-678.
  • 7Huang Dong,Yuan Xiuling,Zhang Xingqun,et al.Effects of fan-starting methods on the reverse-cycle defrost performance of an air-to-water heat pump [J].Int J Refrig,2004,27(8):869-875.
  • 8Kuwahara E,Kawamura T,Yamazaki M.Shorting the defrost time on a heat-pump air-conditioner [J].ASHRAE Transaction,1986,92(2A):20-29.
  • 9Cho H Y,Kim Y C,Jang I Y.Performance of a showcase refrigeration system with multi-evaporator during on-off and hot-gas bypass defrost[J].Energy,2005,102(1):1915-1930.
  • 10Krakow K I,Lin S.Hot-gas bypass defrosting of evaporator utilizing a vaporizer[J].ASHRAE Transaction,1996,102(1):385-394.