期刊文献+

建筑排水用管材(PVC-U)拉伸性能测定的不确定度 被引量:1

Uncertainty in tensile property testing of PVC-U pipes for water discharge in buildings
下载PDF
导出
摘要 在建筑排水用管材硬聚氯乙烯(PVC-U)拉伸性能测定(GB/T8804.2-2003)试验中,通过使用JJF1059-1999《测量不确定度评定与表示》中推荐的方法,根据拉伸性能测定原理建立拉伸屈服应力的测量不确定度数学模型,并讨论了测量不确定度的主要来源,包括:截面积测量偏差、拉力测量偏差、温度效应偏差和拉伸速度偏差。本文通过对以上不确定度分量的分析给出建筑排水用管材(PVC-U)拉伸屈服应力的测量不确定度评定。 This article discusses the uncertainty of tension test(GB/8804.2-2003)of PVC-U pipes for water discharge in buildings.By adopting the method commended by《Evaluation and Expression of the Uncertainty in Measurement》 JJF1059-1999,the math model of uncertainty measurement is suggested based on the philosophy of tension test,and some elements leading to the measurement uncertainty are discussed including sample area,tensile stress,temperature and the speed of tension test.The analysis of those elements leads to the evaluation and expression of the uncertainty in tension test of PVC-U pipes.
作者 袁建宏
出处 《建筑监督检测与造价》 2009年第5期21-23,30,共4页 Supervision Test and Cost of Construction
关键词 PVC-U 拉伸性能 不确定度 评定 PVC-U tensile properties uncertainty evaluation
  • 相关文献

参考文献2

  • 1GB/T 8804.1-2003.热塑性塑料管材 拉伸性能测定 第1部分;试验方法总则[S],2003.
  • 2JJF 1059-1999.测量不确定度评定与表示[S],1999.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部