期刊文献+

Exchange bias for ferromagnetic/antiferromagnetic bilayers with the uniaxial anisotropy being misaligned with the exchange anisotropy 被引量:5

Exchange bias for ferromagnetic/antiferromagnetic bilayers with the uniaxial anisotropy being misaligned with the exchange anisotropy
原文传递
导出
摘要 Using the principle of minimal energy and S-W model,the exchange bias for ferromagnetic/antiferro-magnetic bilayers has been investigated when the uniaxial anisotropy is misaligned with the exchange anisotropy. According to the relation between the energy of the bilayer and the orientation of ferro-magnetic magnetization,it is found that the bilayer will be in the monostable state or bistable state when the external field is absent in the initial magnetization state. The monostable state or bistable state of the bilayer,which determines the angular dependence of exchange bias directly,is controlled by the competition between the exchange anisotropy and uniaxial anisotropy. When the applied field is parallel to the intrinsic easy axes and intrinsic hard axes,one of the switching fields of the hysteresis loop shows an abrupt change,while the other keep continuous by analyzing the magnetization reversal processes. Consequently,the exchange bias field and the coercivity will show a jump phenomenon. The numerical calculations indicate that both the magnitude and direction of the exchange anisotropy will significantly affect the angular dependence of exchange bias. The jump phenomenon of exchange bias is an intrinsic property of the bilayer,which is dependent on the interfacial exchange-coupling constant,the orientation of the exchange anisotropy,the thickness and uniaxial anisotropy constant of the ferromagnetic layer. Using the principle of minimal energy and S-W model, the exchange bias for ferromagnetic/antiferromagnetic bilayers has been investigated when the uniaxial anisotropy is misaligned with the exchange anisotropy. According to the relation between the energy of the bilayer and the orientation of ferromagnetic magnetization, it is found that the bilayer will be in the monostable state or bistable state when the external field is absent in the initial magnetization state. The monostable state or bistable state of the bilayer, which determines the angular dependence of exchange bias directly, is controlled by the competition between the exchange anisotropy and uniaxial anisotropy. When the applied field is parallel to the intrinsic easy axes and intrinsic hard axes, one of the switching fields of the hysteresis loop shows an abrupt change, while the other keep continuous by analyzing the magnetization reversal processes. Consequently, the exchange bias field and the coercivity will show a jump phenomenon. The numerical calculations indicate that both the magnitude and direction of the exchange anisotropy will significantly affect the angular dependence of exchange bias. The jump phenomenon of exchange bias is an intrinsic property of the bilayer, which is dependent on the interfacial exchange-coupling constant, the orientation of the exchange anisotropy, the thickness and uniaxial anisotropy constant of the ferromagnetic layer.
出处 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2009年第12期1885-1892,共8页 中国科学:物理学、力学、天文学(英文版)
基金 Supported by the National Natural Science Foundation of China (Grant No. 10762001) the Program for New Century Excellent Talents in University of China (Grant No. NCET- 05- 0272) the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 200801260003 )
关键词 MONOSTABLE STATE BISTABLE STATE intrinstic easy AXIS intrinstic hard AXIS switching field monostable state bistable state intrinstic easy axis intrinstic hard axis switching field
  • 相关文献

参考文献30

  • 1李明华,于广华,何珂,朱逢吾,赖武彦.具有分隔层Bi的反铁磁/铁磁双层薄膜间的短程交换耦合[J].物理学报,2002,51(12):2854-2857. 被引量:6
  • 2于广华,柴春林,朱逢吾,赖武彦.Interface chemical states of NiO/NiFe films and their effects on magnetic properties[J].Science China(Technological Sciences),2002,45(1):27-34. 被引量:2
  • 3Spenato D,Castel V,Pogossian S P, et al.Asymmetric magnetization reversal behavior in exchange-biased NiFe/MnPt bilayers in two dif- ferent anisotropy regimes: Close and far from critical thickness. Applied Physics Letters . 2007
  • 4Zhou S M,,Li H Y,Yuan S J, et al.Ecvhange bias in ferromagnetic/ antiferromagnetic bilayers. Prog Phys . 2003
  • 5Meiklejohn WH,Bean CP.New Magnetic Anisotropy. Physical Review . 1956
  • 6Meiklejohn WH,Bean CP.New magnetic anisotropy. Physical Review . 1957
  • 7Dieny B.Giant magnetoresistance in spin-valve multilayers. Journal of Magnetism and Magnetic Materials . 1994
  • 8Mauri D,Siegmann HC,Bagus PS,et al.Simple model for thin ferromagnetic films exchange coupled to an antiferromngnetic substrate. Journal of Applied Physics . 1987
  • 9Malozemoff AP.Random-Field Model of Exchange Anisotropy at Rough Ferromagnetic-Antiferromagnetic Interface. Physical Review B: Condensed Matter and Materials Physics . 1987
  • 10Koon N C.Calculations of exchange bias in thin films with ferromagnetic/antiferromagnetic interface. Physical Review . 1997

二级参考文献22

  • 1[1]Grunberg P, Schreiber R, Pang Y et al 1986 Phys.Rev.Lett. 57 2442
  • 2[2]Baich M N, Broto J M, Fert A et al 1988 Phys.Rev.Lett. 61 2472
  • 3[3]Parkin S S P, More N and Roche K P 1990 Phys. Rev. Lett. 60 2304
  • 4[4]Petroff F, Barthelemy A, Mosca D H et al 1991 Phys. Rev. B 44 5353
  • 5[5]Yan M L, Lai W Y and Wang Y Z 1995 J. Appl. Phys. 74 1816Yu C T, Lai W Y, Yan M L et al 1995 Phys. Rev. B 52 1123
  • 6[6]Wang S F, Wang Z C and Zhou Z C 1998 Chin.Phys.Lett. 7 529
  • 7[7]Zhao T Y, Dan Z S, Shen B G and Zhao J G 1998 Chin.Phys.Lett. 7 613
  • 8[8]Gokemeijer N J, Ambrose T and Chien C L 1997 Phys. Rev. Lett. 79 4270
  • 9[9]Mewes T, Roos B F P, Demokritov S O and Hilebrands B 2000 J. Appl. Phys. 87 5064
  • 10[10]Thomas L, Kellock A J and Parkin S S P 2000 J. Appl. Phys. 87 5061

共引文献6

同被引文献16

引证文献5

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部