期刊文献+

HJ-1A HSI on-orbit radiometric calibration and validation research 被引量:10

HJ-1A HSI on-orbit radiometric calibration and validation research
原文传递
导出
摘要 The calibration experiment data at Dunhuang radiometric calibration site in October, 2008 were used to achieve the on-orbit radiometric calibration for HJ-1A hyper spectral imager (HSI). Two other field experiments data were used to validate the Dunhuang calibration results. One field experiment took place in Inner-Mongolia, China in September, 2008, and the other field experiment took place in Lake Frome, Australia in February, 2009. Finally, the ‘confidence interval of calibration error’ concept was put forward for quantitatively computing the calibration coefficient error confidence interval. The results showed that the Dunhuang calibration results in 2008 had high reliability. The confidence intervals of calibration error for all HSI channels were between 2% to 12%, which could satisfy the requirement of the HSI quantitative applications. The calibration experiment data at Dunhuang radiometric calibration site in October, 2008 were used to achieve the on-orbit radiometric calibration for HJ-1A hyper spectral imager (HSI). Two other field experiments data were used to validate the Dunhuang calibration results. One field experiment took place in Inner-Mongolia, China in September, 2008, and the other field experiment took place in Lake Frome, Australia in February, 2009. Finally, the ‘confidence interval of calibration error’ concept was put forward for quantitatively computing the calibration coefficient error confidence interval. The results showed that the Dunhuang calibration results in 2008 had high reliability. The confidence intervals of calibration error for all HSI channels were between 2% to 12%, which could satisfy the requirement of the HSI quantitative applications.
出处 《Science China(Technological Sciences)》 SCIE EI CAS 2010年第11期3119-3128,共10页 中国科学(技术科学英文版)
基金 supported by the International Science and Technology Cooperation Program of China (Grant No 2008DFA21540) the Chinese Defence Advance Research Program of Science and Technology (Grant No 07K00100KJ) the National Hi-Tech Research and Development Pro-gram of China ("863" Project)
关键词 HJ-1A hyper spectral imager(HSI) radiometric calibration VALIDATION confidence interval HJ-1A hyper spectral imager (HSI) radiometric calibration validation confidence interval
  • 相关文献

参考文献11

二级参考文献83

共引文献165

同被引文献74

引证文献10

二级引证文献102

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部