期刊文献+

Radiation force on absorbing targets and power measurements of a high intensity focused ultrasound (HIFU) source

Radiation force on absorbing targets and power measurements of a high intensity focused ultrasound (HIFU) source
原文传递
导出
摘要 Based on the analytic expressions for the radiated field of a circular concave piston given by Hasegawa et al.,an integral for calculation of the radiation force on a plane absorbing target in a spherically focused field is derived.A general relation between acoustic power P and normal radiation force Fn is obtained under the condition of kr 1.Numerical computation is carried out by using the symbolic computation program for practically focused sources and absorbing circular targets.The results show that,for a given source,there is a range of target positions where the radiation force is independent of the target's position under the assumption that the contribution of the acoustic field behind the target to the radiation force can be neglected.The experiments are carried out and confirm that there is a range of target positions where the measured radiation force is basically independent of the target's position even at high acoustic power (up to 700 W).It is believed that when the radiation force method is used to measure the acoustic power radiated from a focused source,the size of the target must be selected in such a way that no observable sound can be found in the region behind the target. Based on the analytic expressions for the radiated field of a circular concave piston given by Hasegawa et al.,an integral for calculation of the radiation force on a plane absorbing target in a spherically focused field is derived.A general relation between acoustic power P and normal radiation force Fn is obtained under the condition of kr 1.Numerical computation is carried out by using the symbolic computation program for practically focused sources and absorbing circular targets.The results show that,for a given source,there is a range of target positions where the radiation force is independent of the target’s position under the assumption that the contribution of the acoustic field behind the target to the radiation force can be neglected.The experiments are carried out and confirm that there is a range of target positions where the measured radiation force is basically independent of the target’s position even at high acoustic power (up to 700 W).It is believed that when the radiation force method is used to measure the acoustic power radiated from a focused source,the size of the target must be selected in such a way that no observable sound can be found in the region behind the target.
出处 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2010年第10期1780-1787,共8页 中国科学:物理学、力学、天文学(英文版)
关键词 Radiation force TARGETS power measurements high intensity focused ultrasound Radiation force targets power measurements high intensity focused ultrasound
  • 相关文献

参考文献15

  • 1Beissner K.Minimum target size in radiation force measurements. The Journal of The Acoustical Society of America . 1984
  • 2Nagy P B.Diffraction correction for a radiation force measurement on an infinite plane target. The Journal of The Acoustical Society of America . 1986
  • 3Shaw A,ter Haar G R.Requirements for measurement standards in high intensity focused ultrasound (HIFU) fields. NPL Report DQL AC015 Appendix C .
  • 4Hasegawa T,Matsuzawa K,Inoue N.A new expansion for the veloc- ity potential of a circular concave piston. The Journal of The Acoustical Society of America . 1986
  • 5Shaw A.How to measure HIFU output power properly. 5th Sym- posium on Therapeutic Ultrasound . 2006
  • 6Zhou Y F,Zhai Liang,Simmons R,et al.Measurement of high inten- sity focused ultrasound fields by a fiber optic probe hydrophone. The Journal of The Acoustical Society of America . 2006
  • 7Beissner K.RADIATION FORCE CALCULATIONS. Acustica . 1987
  • 8Maruvada S,Harris GR,Herman BA, et al.Acoustic power calibration of high-intensity focused ultrasound transducers using a radiation force technique. The Journal of The Acoustical Society of America . 2007
  • 9Shou W,Huang X,Duan S, et al.Acoustic power measurement of high intensity focused ultrasound in medicine based on radiation force. Ultrasonics . 2006
  • 10Westervelt P J.Acoustic radiation pressure. The Journal of The Acoustical Society of America . 1957

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部