摘要 This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and minimal residual deformation. For comparison purpose,an alternate seismic retrofit scheme that uses a bilinear-hysteresis retrofit system such as buckling-restrained braces (BRB) is also considered in this paper. The parametric study was carried out in a single-degree-of-freedom (SDOF) system framework since a multi-story building structure may be idealized as an equivalent SDOF system and investigation of the performance of this equivalent SDOF system can provide insight into the seismic response of the multi-story building. A peak-oriented hysteresis model which can consider the strength and stiffness degradation is used to describe the hysteretic behavior of RC structures. The parametric study involves two key parameters -the strength ratio and elastic stiffness ratio between the seismic retrofit system and the original RC frame. An ensemble of 172 earthquake ground motion records scaled to the design basis earthquake in California with a probability of exceedance of 10% in 50 years was constructed for the simulation-based parametric study. The effectiveness of the two seismic retrofit schemes considered in this study is evaluated in terms of peak displacement ratio,peak acceleration ratio,energy dissipation demand ratio and residual displacement ratio between the SDOF systems with and without retrofit. It is found from this parametric study that RC structures retrofitted with the self-centering retrofit scheme (SCRS) can achieve a seismic performance level comparable to the bilinear-hysteresis retrofit scheme (BHRS) in terms of peak displacement and energy dissipation demand ratio while having negligible residual displacement after earthquake. This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and minimal residual deformation. For comparison purpose,an alternate seismic retrofit scheme that uses a bilinear-hysteresis retrofit system such as buckling-restrained braces (BRB) is also considered in this paper. The parametric study was carried out in a single-degree-of-freedom (SDOF) system framework since a multi-story building structure may be idealized as an equivalent SDOF system and investigation of the performance of this equivalent SDOF system can provide insight into the seismic response of the multi-story building. A peak-oriented hysteresis model which can consider the strength and stiffness degradation is used to describe the hysteretic behavior of RC structures. The parametric study involves two key parameters -the strength ratio and elastic stiffness ratio between the seismic retrofit system and the original RC frame. An ensemble of 172 earthquake ground motion records scaled to the design basis earthquake in California with a probability of exceedance of 10% in 50 years was constructed for the simulation-based parametric study. The effectiveness of the two seismic retrofit schemes considered in this study is evaluated in terms of peak displacement ratio,peak acceleration ratio,energy dissipation demand ratio and residual displacement ratio between the SDOF systems with and without retrofit. It is found from this parametric study that RC structures retrofitted with the self-centering retrofit scheme (SCRS) can achieve a seismic performance level comparable to the bilinear-hysteresis retrofit scheme (BHRS) in terms of peak displacement and energy dissipation demand ratio while having negligible residual displacement after earthquake.
出处 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2010年第2期271-283,共13页 地震工程与工程振动(英文刊)
基金 Univeristy of Maryland,Start-up Grant to the First Author
关键词 EARTHQUAKE REINFORCED concrete FRAME structure nonlinear analysis SDOF system SEISMIC RETROFIT SELF-CENTERING earthquake reinforced concrete frame structure nonlinear analysis SDOF system seismic retrofit self-centering
  • 相关文献

参考文献26

  • 1Anagnos T,Comerio MC,Goulet C,Na H,Steele J,Stewart JP."Los Angeles Inventory of Nonductile Concrete Buildings for Analysis of Seismic Collapse Risk Hazards,". Proc. 14th World Conf. Earthquake Engrg . 2008
  • 2Bracci JM,Reinhorn AM,Mander JB."Seismic Retrofit of Reinforced Concrete Buildings Designed for Gravity Loads: Performance of Structural Model,". ACI Structural Journal . 1995
  • 3Christopoulos C,Filiatrault A,Folz B."Seismic Response of Self-centering Hysteretic SDOF systems,". Earthquake Engineering and Structural Dynamics . 2002
  • 4Garlock MM,Ricles JM,Sause R."Experimental Studies of Full-scale Post-tensioned Steel Connections,". Journal of Structural Engineering ASCE . 2005
  • 5Thermou GE,Elnashai AS."Seismic Retrofi t Schemes for RC Structures and Local-global Consequences,". Progress in Structural Engineering and Materials . 2006
  • 6Goel S,Lee H."Seismic Strengthening of RC Structures by Ductile Steel Bracing System,". Proc. 4th US NCEE . 1990
  • 7Harries K,Ricles J,Sause R,Pessiki S,Walkup L."Seismic Retrof it of Non-ductile Reinforced Concrete Building Columns Using FRPC Jackets,". Proc. 6th US NCEE . 1998
  • 8Kam WY,Pampanin S."Selective Weakening Techniques for Retrofit of Existing Reinforced Concrete Structures,". Proc. 14th World Conf. on Earthquake Engineering (14WCEE) . 2008
  • 9Mahin SA,Bertero VV."Nonlinear Seismic Response of a Coupled Wall System,". ASCE Journal of the Structural Division . 1976
  • 10Panian L,Steyer M,Tipping S."Post-tensioned Concrete Walls for Seismic Resistance,". PTI Journal . 2007