期刊文献+

心理辅导对肿瘤患者行18F-FDG PET肿瘤代谢显像质量的影响

Nursing care of patients psychological counseling and regulating blood sugar concentration for 18F-FDG PET scan
下载PDF
导出
摘要 目的探讨心理辅导对肿瘤患者行18F-FDG(氟代脱氧葡萄糖)正电子发射型计算机断层显像图像质量的影响。方法94例肿瘤患者常规行18F-FDG显像。将其随机分2组:有心理辅导组62例,心理辅导内容包括检查前与患者交流,消除不良心理因素,讲解显像注意事项,防止剧烈运动,嘱患者检查后多饮水加快放射性药物的排泄;控制患者血糖于正常范围;注射药物后嘱患者静卧休息,听轻松愉快的音乐。无心理辅导组32例。对2组显像时的肌肉显影情况进行对比分析。结果与无心理辅导组相比,心理辅导组肿瘤显像清晰度满意,图像质量佳,2组差异有统计学意义(p<0.05)。结论心理辅导可消除患者不良情绪、合理控制血糖水平、减少肌肉收缩活动,对保障18F-FDG肿瘤代谢显像质量、实现影像分析并最终作出正确诊断具有重要作用。 Objective:to diagnosis of 94 cases of tumor patients,18F-FDG PET scan were performed.Experiences of the performing procedure were summarized.Methods:A total of 94 cases of tumor patients were performed 18F-FDG PET scan as routine,and were randomly divide into two groups:nursing care 62 cases and non-nursing care 32 cases.Analysis the situation of muscle absorbs 18F-FDG of two groups.Nursing care group including psychological counseling and regulating blood sugar concentration.Rest in bed after they were injected 18F-FDG,and listen of some light music.In order to made body keep quiet when 18F-FDG PET scan.Results:Nursing care group,the quality of l8F-FDG PET scan was satisfied,while the quality of 18F-FDG PET scan non-nursing care group,in was unsatisfied.Conclusion:To relax the mood of patients and control blood sugar at a reasonable level may ensure the quality of 18F-FDG PET scan,which is the basis of making correct diagnosis.It is the key points to control blood sugar level reasonably,and strength their mental care is very importantfor.
出处 《当代护士(下旬刊)》 2009年第9期49-50,共2页 Modern Nurse
关键词 氟代脱氧葡萄糖 代谢显像 心理辅导 血糖 护理 18F-FDC Metabolism Development Psychological Counseling Blood Glucose Nursing Care
  • 相关文献

参考文献6

二级参考文献23

  • 1Kadrmas DJ, Christian PE. Comparative evaluation of lesion detectability for 6 PET imaging platforms using a highly reproducible whole-body phantom with (22)Na lesions and localization ROC analysis[J]. J Nucl Med, 2002, 43( 11 ): 1545-1554.
  • 2Bettinardi V, Pagani E, Gilardi MC. Implementation and evaluation of a 3D one-step late reconstruction algorithm for 3D positron emission tomography brain studies using median root prior[J]. Eur J Nucl Med Mol Imag, 2002, 29 ( 1 ): 7-18.
  • 3IAEA-TECDOC-602, Quality Control of Nuclear Medicine Instruments[S].
  • 4Lartizien C, Kinahan PE, Swensson R, et al. Evaluating image reconstruction methods for tumor detection in 3-dimensional wholebody PET oncology imaging[J]. J Nucl Med, 2003, 44(2): 276-290.
  • 5Zaidi H. Reconstruction-based estimation of the scatter component in positron emission tomography[J]. Ann Nucl Med Sci, 2001, 14: 161-172.
  • 6Ak I, Blokland JA, Pauwels EK, et al. The clinical valve of 18F-FDG detection with a dual-head coincidence camera: a review [J]. Eur J NuclMed, 2001, 28(6): 763-778.
  • 7Zaidi H, Hasegawa B. Determination of the attenuation map in emission tomography[J]. J Nucl Med, 2003, 44(2): 291-315.
  • 8Nakamoto Y, Osman M, Cohade C, et al. PET/CT: comparison of quantitative tracer uptake between germanium and CT transmission attenuation-corrected images[J]. J Nucl Med, 2002, 43 (9): 1137- 1143.
  • 9Osman MM, Cohade C, Nakamoto Y, et al. Clinically significant in accurate localization of lesions with PET/CT: frequency in 300 patients[J]. J Nucl Med, 2003, 44(2): 240-243.
  • 10Beyer T, Townsend DW, Brun T, et al. A conbined PET/CT scanner for clinical oncology[J]. J Nucl Med, 2000, 41:1369-1379.

共引文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部