期刊文献+

ProTaper手动镍钛锉与手用不锈刚K锉预备弯曲根管效果对比研究

A comparison study of apical deviation of curved canals with ProTaper Nikel-Titanium hand-files and stainless steel K-files
原文传递
导出
摘要 目的比较ProTaper手动镍钛锉和手用不锈钢K锉对弯曲根管的预备效果。方法选择2006年3月至2007年3月辽宁省人民医院口腔门诊收治的前磨牙和磨牙患有牙髓炎和根尖周炎,且有弯曲根管的患者92例,随机分为两组,分别采用ProTaper手动镍钛锉(PT组)和手用不锈钢K锉(SS组)进行根管预备,侧向加压技术充填根管,比较两组根管曲度的变化。结果PT组根管曲度平均减小1.97°,SS组根管曲度平均减小9.48°,两组比较,差异有统计学意义(P<0.05)。结论ProTaper手动镍钛锉可以很好地保持根管的初始走向,且并发症减少。 Objective To compare the result of curved canal preparation with ProTaper Nikel-Titanium hand-files and stainless steel K-files.Methods Totally 92 premolars and molars with curved canals suffering from pulpitis and periapical periodontitis were equally divided into two groups randomly;canals were prepared with ProTaper Nikel-Titanium hand-files and stainless steel K-files. Results ProTaper Nikel-Titanium hand-files averagely minished 1.97°;stainless steel K-files averagely minished 9.48°;the two groups had a significant difference. Conclusion ProTaper Nikel-Titanium hand-files can better deviation retained primary direction and reduce complications.
出处 《中国实用口腔科杂志》 CAS 2009年第11期680-681,共2页 Chinese Journal of Practical Stomatology
关键词 根管预备 根尖偏移 弯曲根管 root canal preaparation apical transportation curved canals
  • 相关文献

参考文献7

  • 1李勇刚,林媛,沙鑫家,吴补领,郭戈.两种K型锉预备弯曲人工根管效果的比较[J].牙体牙髓牙周病学杂志,2003,13(2):85-87. 被引量:24
  • 2范兵,樊明文,边专,吴民凯,P.R.Wesselink.根管偏移对充填材料封闭根管能力的影响[J].口腔医学纵横,2001,17(2):83-87. 被引量:62
  • 3Schneider SW.A comparison of canal preparations in straight and curved root canals. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology . 1971
  • 4Imfeled T N.Prevalence and quality of endodontic treatment in elderly urban population of Switzerland. Journal of Endodontics . 1991
  • 5Wildey W L,Senia E S.A new root canal instrument and instrumentation technique: a preliminary report. Oral Surg Oral Med Oral Pathol . 1989
  • 6Schafer E,Lohmann D.Efficiency of rotary nickel-titanium Flex Master instruments compared with starnless steel hand K-Flexcfile-part 1.Shaping ability in simulated curvedcanals. International Endodontic Journal . 2002
  • 7Coleman CL,Svec TA,Rieger MR,et al.Analysis of nickel -titanium versus stainless steel instrumentation by means of direct digital imaging. Journal of Endodontics . 1996

二级参考文献16

  • 1Gary chueng.镍钛机用根管器械的临床应用和注意事项[J].牙体牙髓牙周病学杂志,1999,9:7-7.
  • 2[4]Schneider SW.A comparison of canal preparations in straight and curved canals.Oral Surg Oral Med Oral Pathol,1971,32∶271-275
  • 3[5]Lightspeed Technology Inc.Lightspeed reference guide.11707 Raindop Drive,San Antonio,TX,USA:Lightspeed Technology,1994
  • 4[6]Walton R.Cleaning and shaping.In:Walton R,Torabinejad M.Principles and practice of Endodontics.Philadelphia:Sunders,1989,202-204
  • 5[7]Walton R.Obturation.In:Walton R,Torabinejad M.Principles and practice of Endodontics.Philadelphia:Sunders,1989,247-251
  • 6[8]Rybicki R,Zillich R.Apical sealing ability of Thermafil following immediate and delayed post space preparations.J Endod,1994,20∶64-66
  • 7[9]Fan B,Wu MK,Wesselink PR.Coronal leakage along apical root fillings after immediate and delayed post space preparation.Endod Dent Traumatol,1999,15∶124-126
  • 8[10]Southyard DW,Oswald RJ,Natkin E.Instrumentation of curved molar root canals with the Roane technique.J Endod,1987,13∶479-489
  • 9[11]Ehrlich AD,Boyer TJ,Hicks ML,Pelleu GB.Effects of sonic instrumentation on the apical preparation of curved canals.J Endod,1989,15∶200-203
  • 10[12]Wu M-K,De Gee AJ,Wesselink PR,Moorer WR.Fluid transport and bacteria penetration along root canal fillings.Int Endod J,1993,26∶203-208