摘要 To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes. To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes.
出处 《Journal of Central South University》 SCIE EI CAS 2009年第S1期6-11,共6页 中南大学学报(英文版)
基金 Project(50838009) supported by the National Natural Science Foundation of China Projects(2006BAJ02A09,2006BAJ02A13-4) supported by the National Key Technologies R & D Program of China
关键词 AIR-CONDITIONING TEMPERATURE thermal COMFORT AIR-CONDITIONER energy consumption NEUTRAL TEMPERATURE acceptable TEMPERATURE air-conditioning temperature thermal comfort air-conditioner energy consumption neutral temperature acceptable temperature
  • 相关文献

参考文献4

二级参考文献10

  • 1中华人民共和国建设部.夏热冬暖地区居住建筑节能设计标准(JGJ75-2003)[S].北京:中国计划出版社,2003
  • 2国家质量技术监督局,中等热环境PMV和PPD指数的测定及热舒适条件的规定(GB/T18049-2000)[S].北京:中国标准出版社,2000
  • 3Li Li. Thermal comfort characteristic of inhabitant and thermal comfort predicting in summer [J]. Journal of Harbin Institute of Technology, 2007, 14(Sup.): 197-200
  • 4中华人民共和国建设部.采暖通风与空气调节设计规范(GB50019-2003)[S].北京:中国计划出版社,2003.
  • 5陆耀庆,陈涛.实用供热空调设计手册[M].中国建筑工业出版社,1996,6.
  • 6GAGGE A P FOBELETS,L G BERGLUND.A standard predictive index of human response to the thermal environment[J].ASHRAE Transactions,1986,92(2B):709 ~ 730.
  • 7ASHRAE Handbook of fundamentals[M].Chapter 8,Thermal comfort.ASHRAE,2001.
  • 8清华大学DeST开发组.建筑环境系统模拟分析方法-DeST[M].北京:中国建筑工业出版社,2006:310-311.
  • 9国务院办公厅.关于严格执行公共建筑空调温度控制标准的通知[R].国办发[2007]42号,2007年6月1日
  • 10福建建筑科学研究院.DBJ13-62-2004.福建省居住建筑节能设计标准实施细则[S].2004.