摘要
分析了汶川地震中钢结构厂房钢管柱间支撑的震害原因,指出钢管直接焊接连接节点塑性变形能力差,引起应力集中而破坏。文中提出钢管柱间支撑节点构造的改进措施,供工程实践参考。
Earthquake disaster for steel-tube intercolumnar brace of steel structure factory buildings in the Wenchuan Earthquake is analyzed.Direct-welded joints of steel-tube are not provided with plastic deformation capability,and lead to damage by stress concentration.In the paper details of steel-tube intercolumnar brace are improved.
出处
《建筑结构》
CSCD
北大核心
2009年第S2期322-323,共2页
Building Structure
关键词
钢管结构
震害
柱间支撑
节点构造
steel-tube structure
earthquake disaster
intercolumnar brace
details