期刊文献+

招商银行上海大厦模型振动台试验研究 被引量:1

Analysis of Shaking Table Test of the CMB Shanghai Building
原文传递
导出
摘要 招商银行上海大厦由南北两个塔楼和塔楼间的大跨度连桥组成,均属于平面和竖向均不规则的抗震超限建筑。本文介绍了对该结构进行1:25缩尺模型的模拟振动台试验。对试验结果的分析表明:招商银行上海大厦的南塔楼、北塔楼结构均可以满足的三水准抗震设防要求,连桥结构在满足三水准抗震设防要求的前提下,可以满足中震时节点处于弹性受力状态,大震不屈服的设计目标。此外,还证实了连桥钢桁架与混凝土筒体连接节点是连桥结构的薄弱部位。 China Merchants Bank Shanghai Building is composed of the North and the South Tower,a large-span link-bridge between the two towers.The configuration of the horizontal and vertical plan does not satisfy the rules of the seismic code.This article gives a introduction to the shaking table test of a 1;25 scale model.The results of the test shows that the behavour of the north tower structure、south tower structure and the link-bridge structure can meet the requirement of the three-level seismic-resisting design.And the link-bridge structure can also remain elastic node under medium-level earthquake,does not yield under rare-level earthquake.In addition,the test shows that the joint of the link-bridge and the concrete tube is the weakest part of the link-bridge structure.
出处 《建筑结构》 CSCD 北大核心 2009年第S1期581-583,共3页 Building Structure
关键词 高层混合结构 大跨度连体结构 振动台试验 high-level mixed structure large-span link-bridge structures shaking table test
  • 相关文献

同被引文献6

  • 1贾京,周春,曲宏,王湧,王沁平.招商银行上海大厦连桥型钢混凝土节点分析与试验[J].建筑结构,2011,41(S1):1101-1104. 被引量:2
  • 2ANSYS中国公司.Ansys非线性分析指南[M].北京,2000.
  • 3中华人民共和国住房和城乡建设部.GB50011—200l建筑抗震设计规范[S].北京:中围建筑工业出版社,2001.
  • 4上海市城乡建设和交通委员会.DJG08-9-2003建筑抗震设计规程[S].上海,2003.
  • 5顾祥林,林峰,陈涛.招商银行上海大厦钢构件模型单调加载试验报告[R].上海:同济大学建筑工程系,2008.
  • 6程绍革,白雪霜,王齐.招商银行上海大厦结构模型模拟地震振动台试验报告[R].北京:中国建筑科学研究院工程抗震研究所,2009.

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部