摘要 对没有防火保护的钢管混凝土柱的抗火性能及其分析方法进行研究。通过没有防火保护的配筋钢管混凝土柱的火灾试验,研究了配筋钢管混凝土柱的火灾行为、截面温度场、变形和耐火极限,试验结果表明配筋可以显著提高钢管混凝土柱的耐火极限。探讨了配筋钢管混凝土柱抗火性能的数值模拟方法,在数值模拟中考虑了水分、接触热阻和高温瞬态热应变的影响,通过与试验结果的对比表明数值方法可以较好地计算柱的变形和耐火极限,并且能够满足工程应用的精度要求。最后在数值计算结果和试验结果的基础上,给出了配筋钢管混凝土柱截面温度场和耐火极限的简化计算方法,以方便实用。 The fire-resistance performance and analytical method of concrete filled steel tubular columns without fire protection were investigated.Fire tests were carried out to study the fire behaviors,section temperature fields,deformations,and fire resistance of bar-reinforced concrete filled steel tubular columns without fire protection.The experimental results indicate that the fire resistance can be obviously increased by the steel reinforcement allocated in the columns.The numerical method to simulate the fire resistance of bar-reinforced concrete filled steel tubular columns was discussed,and the effects of water,contact thermal resistance,and transient thermal strain were taken into account in this method.Calculated results were compared with experimental values demonstrating that the numerical method is capable of calculating the deformations and fire resistance of the columns with an accuracy that is adequate for practical purposes.Finally,simplified calculation methods,which are convenience to practices,were presented on the basis of numerical and experimental results to calculate the section temperature field and fire resistance of bar-reinforced concrete filled steel tubular columns.
出处 《建筑结构学报》 EI CAS CSCD 北大核心 2009年第S2期265-270,共6页 Journal of Building Structures
基金 国家"十一五"科技支撑计划重点项目"大型及重要建筑安全监测预警集成技术研究与示范"(2006BAJ13B03)
关键词 配筋钢管混凝土柱 试验 数值模拟 简化计算方法 耐火极限 bar-reinforced concrete filled steel tubular columns tests numerical simulation simplified calcultion method fire resistance
  • 相关文献

参考文献15

二级参考文献58

  • 1李卫,过镇海.高温下砼的强度和变形性能试验研究[J].建筑结构学报,1993,14(1):8-16. 被引量:250
  • 2过镇海,李卫.混凝土在不同应力-温度途径下的变形试验和本构关系[J].土木工程学报,1993,26(5):58-69. 被引量:66
  • 3European Committee for Standardization.Eurocode No.1,General actions,Part 1.2:Actions on structures exposed to fire(ENV 1991-1-2)[S].London:British Standards Institution,2002.
  • 4European Committee for Standardization.Eurocode No.4,Design of steel and composite structures,Part1.2:General rules-structural fire design(ENV 1994-1-2)[S].London:British Standards Institution,2002.
  • 5韩金生.配筋钢管混凝土柱抗火性能的试验研究[D].南京:东南大学,2006.
  • 6中华人民共和国公安部.建筑构件耐火试验方法(GB/T 9978.1-2008)[S].北京:中国标准出版社,2008.
  • 7LIE T T.Fire resistance of circular steel columns filled with bar-reinforced concrete[J].Journal of Structural Engineering,1994,120(5):1489-1509.
  • 8KODUR V K R,LIE T T.Fire resistance of circular steel columns filled with fibre-reinforced concrete[J].Journal of Structural Engineering,1996,122(7):776-782.
  • 9KODUR V K R.Performance of high strength concrete-filled steel columns exposed to fire[J].Canadian Journal of Civil Engineering,1998,25:975-981.
  • 10WANG Y C.A simple method for calculating the fire resistance of concrete-filled CHS columns[J].Journal of Constructional Steel Research,2000,54:365-386.

共引文献122

同被引文献58

引证文献10

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部