摘要
文章阐述了通过在胜利油田利津污水站工艺流程中增设一次除油罐、双滤料过滤器、精细过滤器,改造混凝沉降罐,并采用分别供水等措施,解决了污水站处理的污水因来源发生变化,污水性质发生变化,从而不能达标处理的问题。
In the process modification of Lijin Sewage Station,by means of adding a primary oil removal tank,a filter with double filtering materials,a fine filter and reforming a coagutation sedimentation tank and adopting separative water supply,the sewage problems at Lijin Sewage Station caused by changed sewage source and changed sewage properties are solved.The sewage treatment quality reaches relevant standard.
出处
《石油工程建设》
2009年第S1期162-164,5,共4页
Petroleum Engineering Construction
关键词
油田采出污水
污水处理工艺
工艺改造
oilfield produced sewage
sewage treatment process