摘要 Based on the optimized design of the lattice for therapy synchrotron and considering the requirement of radiation therapy, the third order resonant extraction is adopted. Using the momentum-amplitude selection method, the extraction system is designed and optimized. An extraction efficiency of more than 97% and a momentum spread less than 0.11% are obtained. Based on the optimized design of the lattice for therapy synchrotron and considering the requirement of radiation therapy, the third order resonant extraction is adopted. Using the momentum-amplitude selection method, the extraction system is designed and optimized. An extraction efficiency of more than 97% and a momentum spread less than 0.11% are obtained.
出处 《Chinese Physics C》 SCIE CAS CSCD 2009年第S2期30-32,共3页 中国物理C(英文版)
基金 Supported by Key Equipment R & D Fund of CAS (0713040YZ0)
关键词 slow extraction third order resonance SYNCHROTRON slow extraction, third order resonance, synchrotron