期刊文献+

我国规范用于计算其他强度冷弯薄壁型钢梁的适用性

THE APPLICABILITY OF CALCULATION OF OTHER THAN Q235 OR Q345 COLD-FORMED STEEL BEAMS USING CHINESE CODE
原文传递
导出
摘要 尝试将我国GB 50018-2002《冷弯薄壁型钢结构技术规范》用于计算屈服强度不是Q235和Q345的钢材制成的冷弯薄壁型钢梁,并将我国规范计算结果与试验结果、国外规范计算结果相比较。对于发生局部屈曲的梁,我国规范计算结果安全;结果表明:对于发生畸变屈曲的梁,我国规范计算结果不安全。 The cold-formed thin-walled steel beams whose yield strengths are not Q235 or Q345 are calculated with Chinese code GB 50018-2002 in this paper.As compared with the results of a series of tests and other standards abroad,the predictions of Chinese code are safe for the beams failed by local buckling and not safe for the beams failed by distortional buckling.
作者 惠颖 余巧萍
机构地区 南京理工大学
出处 《工业建筑》 CSCD 北大核心 2009年第S1期506-510,共5页 Industrial Construction
关键词 规范 屈服强度 冷弯薄壁型钢梁 试验 code yield strength cold-formed thin-walled steel beam test
  • 相关文献

参考文献4

  • 1Yang D,Hancock G J.Compression Tests of Cold-ReducedHigh Strength Steel Sections:I-Stub Columns[].Jof Struc-tural EngineeringASCE.2004
  • 2Nguyen N T B,Fung T C,Young B.Strength and Behaviour of Cold-Formed Steel Z-Sections Subjected to Major Axis Bending[].Journal ofStructural Engineering.2006
  • 3Cheng Yu,Benjamin W.Schafer Distortional Buckling Test onCold-formed Steel Beams[].Journal of Structural Engineering ASCE.2006
  • 4Cheng Yu,Benjiamin W Schafer.Local Buckling Tests on Cold-Formed Steel Beams[].Journal of Structural Engineering ASCE.2003