期刊文献+

双源CT冠状动脉血管成像的临床应用 被引量:6

Clinical application of coronary angiography by dual-source CT
下载PDF
导出
摘要 冠状动脉性心脏病是一种常见病、多发病。双源CT以极高时间分辨率和高空间分辨率的优势,可以不依赖心率进行冠状动脉数据采集,获得满意的影像质量,使临床适应范围更宽,诊断更加准确,真正满足了临床冠状动脉疾病检查的需要,无疑也是目前冠状动脉最好的无创检查方法。本文综述双源CT的基本特点和在冠状动脉血管成像中的临床应用。 Coronary artery disease is a common,frequently-occurring disease.With the advantage of high temporal resolution and high spatial resolution,dual-source CT(DSCT)obtains high-quality images no longer to depend on heart rate.So that,it has a wider range of clinical adaptation and a more accurate diagnosis.It truly enable to meet the need for the examination of coronary artery disease and is undoubtedly the best non-invasive method of examination at present.This article provided a review of basic characteristics and clinical applications of DSCT.
出处 《中国医学影像技术》 CSCD 北大核心 2009年第S1期206-209,共4页 Chinese Journal of Medical Imaging Technology
关键词 冠状动脉 双源CT 血管成像术 Coronary artery Dual-source computed tomography Angiography
  • 相关文献

参考文献3

二级参考文献20

共引文献92

同被引文献40

  • 1吴岩,陆子琳,王克超.双源CT在心源性疾病中的临床应用[J].昆明医科大学学报,2009,32(S1):129-132. 被引量:2
  • 2张兆琪,马晓海.64层螺旋CT冠状动脉成像——无创性冠状动脉检查的新纪元[J].中华放射学杂志,2006,40(8):789-791. 被引量:88
  • 3郭华,张龙江,江时森,王立军,钟勇,汤沂,卢光明.双源CT成像在评价冠状动脉狭窄中价值的初步探讨[J].医学研究生学报,2007,20(7):727-730. 被引量:46
  • 4Wang G, Yu H, De Man B. An outlook on X-ray CT research and development. Med Phys, 2008,35(3) :1051 -1064.
  • 5Leschka S, Scheffel H, Desbiolles L, et al. Image quality and re construction intervals of dual-source CT coronary angiography Recommendations for ECG-pulsing windowing. Invest Radiol 2007,42(8):543- 549.
  • 6Alkadhi H, Scheffel H, Desbiolles L, et al. Dual-source compu ted tomography coronary angiography : Influence o{ obesity, calci um load, and heart rate on diagnostic accuracy. Eur Heart J 2008,29(6) :766-776.
  • 7Ferencik M, Nomura CH, Maurovich-Horvat P, et al. Quantita- tive parameters of image quality in 64-slice computed tomography angiography of the coronary arteries. Eur J Radiol, 2006,57(3) : 373-379.
  • 8Achenbach S, Giesler T, Ropers D, et al. Comparison of image quality in contrast-enhanced coronary-artery visualization by electron beam tomography and retrospectively electrocardiogram- gated multislice spiral computed tomography. Invest Radiol, 2003,38(2) :119- 128.
  • 9Ferencik M, Moselewski F, Ropers D, et al. Quantitative param- eters of image quality in muhidetector spin 1 computed tomographic coronary imaging with submillimeter colimation. Am J Cardiol, 2003,92(11) : 1257-1262.
  • 10Lembcke A, Wiese TH, Schnorr J, et al. Image quality of nonin vasive coronary angiography using multislice spiral computed tomography and electron beam computed tomography: lntraindividual comparison in an animal model. Invest Radiol, 2004, 39 (6) :357-364.

引证文献6