摘要
某型弹用管控处理装置在环境应力筛选试验高温阶段出现通讯异常现象,对故障产生的原因进行了查找和分析,最终得出是由于器件选用时考虑不周导致信号在高温出现时序判读错误,由此及时解决了问题并从中获得宝贵经验和启示。
A communication abnormity phenomenon appears in manager device used in a missle when tested in ESS high temperature time.This paper finds and analyses the matter bringing the failure.Finally we conclude the wrong time sequence judgment owe to inconsiderately choice of parts of an apparatus.At last this problem is resolved preferably.At the same time we gain the valuable experience and revelation.
出处
《火力与指挥控制》
CSCD
北大核心
2009年第S1期95-96,99,共3页
Fire Control & Command Control
关键词
管控处理装置
通讯
分析
manager device,communication,analysis