文中分析了各电信运营商所普遍使用的阀控式密封型铅酸蓄电池(VRLA电池)的使用状况,蓄电池过放电的后果,以及其损坏后对各电信运营商造成的不利影响。同时就如何有效地保护蓄电池组提出了一种新的解决方案,即"蓄电池保护器"的方案,从工作原理及电路等方面对蓄电池保护器进行了详细地介绍和说明。最后就蓄电池保护器的实际使用情况和带来的经济效益进行了总结。
First,the paper makes analysis on the operation status,over-discharge consequence of batteries which are widely used in operators and the bad effect of over-discharge to operators.Then,it presents a novel solution on battery protection,that is,battery protector solution.It illustrates in detail its operation principle and scheme.At the end,the paper makes conclusion on the practice application and the economic benefit of the said battery protector.
出处
《通信电源技术》
2009年第S1期49-50,58,共3页
Telecom Power Technology
关键词
蓄电池
过放电
保护器
battery
over-discharge,protector