期刊文献+

Thermal Performance of Building Roof with Infrared Reflective Coatings 被引量:1

Thermal Performance of Building Roof with Infrared Reflective Coatings
下载PDF
导出
摘要 This paper investigated the applicability and effects of infrared reflective coating on energy consumption of factory building in hot summer and warm winter zone.It first resorted to theoretical calculation,which demonstrated the beneficial effects of infrared reflective coating on reducing building energy consumption.Then it analyzed a field measurement done on two identical rooms respectively with ordinary coated roof and infrared reflective coated roof from November 2006 to October 2007,on a 24h basis.The measured data include exterior and interior roof surface temperature,indoor air temperature,and indoor globe temperature.The related weather data is from a weather station near the measured area.The continuous measurement has been accomplished in southern China,and the measured data indicate that roof surface temperature and heat gain are significantly decreased in summer while slight negative effects in winter are induced by adopting infrared reflective coating.Thus it is simple and applicable to reduce building energy consumption in this area by applying infrared reflective coating.Regress equation between reduced roof thermal property,such as surface temperature and heat gain,and reduction in absorbed solar radiation shows their highly linear relationship.Based on the measured data,it is estimated that the reduced power consumption is 3.45 kWh/m2·month in June. This paper investigated the applicability and effects of infrared reflective coating on energy consumption of factory building in hot summer and warm winter zone.It first resorted to theoretical calculation,which demonstrated the beneficial effects of infrared reflective coating on reducing building energy consumption.Then it analyzed a field measurement done on two identical rooms respectively with ordinary coated roof and infrared reflective coated roof from November 2006 to October 2007,on a 24h basis.The measured data include exterior and interior roof surface temperature,indoor air temperature,and indoor globe temperature.The related weather data is from a weather station near the measured area.The continuous measurement has been accomplished in southern China,and the measured data indicate that roof surface temperature and heat gain are significantly decreased in summer while slight negative effects in winter are induced by adopting infrared reflective coating.Thus it is simple and applicable to reduce building energy consumption in this area by applying infrared reflective coating.Regress equation between reduced roof thermal property,such as surface temperature and heat gain,and reduction in absorbed solar radiation shows their highly linear relationship.Based on the measured data,it is estimated that the reduced power consumption is 3.45 kWh/m2·month in June.
出处 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期151-155,共5页 Journal of Hunan University:Natural Sciences
关键词 INFRARED REFLECTIVE coating hot SUMMER and WARM WINTER zone measurement REFLECTIVITY infrared reflective coating hot summer and warm winter zone measurement reflectivity
  • 相关文献

参考文献2

二级参考文献4

  • 1.JGJ75-2003 夏热冬暖地区居住建筑节能设计标准[S].中国建筑工业出版社,2003..
  • 2.GB50176-93 民用建筑热工设计规范[S].中国计划出版社,1993..
  • 3.JGJ134-2001 夏热冬冷地区居住建筑节能设计标准[S].中国建筑工业出版社,2001..
  • 4四川省建筑科学研究院.JGJ/T14-2004混凝土小型空心砌块建筑技术规程[S].北京:中国建筑工业出版社,2004.

共引文献10

同被引文献6

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部