摘要
合肥发电厂3号汽轮机组真空严密性试验一直不合格,文中论述了对此问题的原因分析和解决方法,特别是高、中压外缸的法螺加热汽柜和外缸法兰加热装置等处的泄漏比较特殊,对于其它同类型机组同类问题的解决具有一定的借鉴意义。
In Hefei power plant,the test of vacuum tightness of NO.3 unit had not been passed for a long time. The paper details its analysis of cause and treatment,especially for searching some important leakage points, especially such as steam heating box of flames for high and medium pressure out cases and flanges heating facilities for out cases of steam turbine,and it will be consulted by other works who have same type units and same type problems.
出处
《安徽电力》
2008年第3期44-46,共3页
Anhui Electric Power