期刊文献+

Feedback Control of Plasma Current and Horizontal Position in HT-7

Feedback Control of Plasma Current and Horizontal Position in HT-7
下载PDF
导出
摘要 There is a strong magnetic coupling between poloidal field coils of superconducting tokamak HT-7, especially between ohinic heating and vertical field coils. These coils are connected to individual power supply. The control system for the plasma current and horizontal position control has been designed and showed satisfactory results with the feedback control of multivari- able feedforward-decoupling and var-parameter PID controller to simultaneously modulate power supplies. The design and analysls of the control system is presented. There is a strong magnetic coupling between poloidal field coils of superconducting tokamak HT-7, especially between ohinic heating and vertical field coils. These coils are connected to individual power supply. The control system for the plasma current and horizontal position control has been designed and showed satisfactory results with the feedback control of multivari- able feedforward-decoupling and var-parameter PID controller to simultaneously modulate power supplies. The design and analysls of the control system is presented.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第4期859-863,共5页 等离子体科学和技术(英文版)
  • 相关文献

参考文献3

  • 1E.Bertolini,et all.The JET magnet power supplies and plasma control systems[].Fusion Technology.1987
  • 2A.Wieczorek,M.Blaumoser,R.Fink,J Oswald,J Schwarz,K.H.Vogtle.Power supplies andprotection system for plasma stabilisation in theASDEX Upgrade tokamak[].IEE PROCEDINGS-B.1992
  • 3Fermani G.et al.Experimental Results and Up-grading of the Plasma Current and Position Con-trol in FTU[].Proc th Symp Fusion Technol-ogy.1992

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部