期刊文献+

Experim ental Study of China-madeJiu Ling Solid Pyrolytic Carbon BileafletProsthetic Heart Valve In Sheep

Experimental Study of China-made JiuLing Solid Pyrolytic Carbon Bileaflet Prosthetic Heart Valve In Sheep
下载PDF
导出
摘要 To assess the hemodynamic performance and biocompatibility of China-made solid pyrolytic carbon bileaflet valve prosthesis so as to provide evidences for clinical trial,fifteen sheep aged 5-6 months underwent mitral replacement with 21-mm JiuLing valve under cardiopulmonary bypass. The first ten sheep underwent preliminary study to establish the trial methods and the matching of animal weight and prosthesis size, other five underwent formal experiment. The hemodynamic parameters of the prosthesis were determined by means of open cardiac catheterization and echocardiography intraoperatively and 2.5 years after operation respectively. The biocompatibility was evaluated by observing animal survival and valve thrombosis or thromboembolism.In result,all of the five sheep undergoing formal experiment survived well. There were no any prosthesis-related complications including mechanical valve failures, endocarditis, thrombosis, thromboembolism, and paravalvular leak. The transvalvular gradients were 5.2±1.7mmHg, 6.1±0.3mmHg and 6.8±0.4mmHg, the former was measured by catheterization intraoperatively, the two later were achieved by catheterization and echocardiography respectively 2.5 years after operation. The gradients increased mildly with the marked increase in cardiac output under dobutamine stress.The results of this study demonstrated that the JiuLing valve prosthesis has good biocompatibility and excellent hemodynamic performance. To assess the hemodynamic performance and biocompatibility of China-made solid pyrolytic carbon bileaflet valve prosthesis so as to provide evidences for clinical trial,fifteen sheep aged 5-6 months underwent mitral replacement with 21-mm JiuLing valve under cardiopulmonary bypass. The first ten sheep underwent preliminary study to establish the trial methods and the matching of animal weight and prosthesis size, other five underwent formal experiment. The hemodynamic parameters of the prosthesis were determined by means of open cardiac catheterization and echocardiography intraoperatively and 2.5 years after operation respectively. The biocompatibility was evaluated by observing animal survival and valve thrombosis or thromboembolism.In result,all of the five sheep undergoing formal experiment survived well. There were no any prosthesis-related complications including mechanical valve failures, endocarditis, thrombosis, thromboembolism, and paravalvular leak. The transvalvular gradients were 5.2±1.7mmHg, 6.1±0.3mmHg and 6.8±0.4mmHg, the former was measured by catheterization intraoperatively, the two later were achieved by catheterization and echocardiography respectively 2.5 years after operation. The gradients increased mildly with the marked increase in cardiac output under dobutamine stress.The results of this study demonstrated that the JiuLing valve prosthesis has good biocompatibility and excellent hemodynamic performance.
出处 《Chinese Journal of Biomedical Engineering(English Edition)》 2000年第1期18-25,共8页 中国生物医学工程学报(英文版)
关键词 Heart Valve PROSTHESIS Laboratory ANIMALS HEMODYNAMICS BIOCOMPATIBLE Materials Heart Valve Prosthesis, Laboratory Animals, Hemodynamics, Biocompatible Materials
  • 相关文献

参考文献7

  • 1Izzat MB,Birdi I,Wilde P,et al.Comparison of hemodynamic performances of St.Jude Medical and CarboMedics 21 mm aortic prostheses by means of Dobutamine stress of echocardiography. Journal of Thoracic and Cardiovascular Surgery . 1996
  • 2Emery RW,Mettler E,Nicoloff DM.A new cardiac prosthesis: The St.Jude Medical valve in vivo resutls. Circulation . 1979
  • 3Laske A,Jenni R,Maloigne M,et al.Pressure gradients across bileaflet aortic valves by direct measurement and echocardiography. The Annals of Thoracic Surgery . 1996
  • 4Kadir I,Izzat MB,Birdi I,et al.Hemodynamic performance of the 21 - mm St.Jude BioImplant prosthesis using dobutamine Doppler echocardiography. The American Journal of Cardiology . 1998
  • 5Palma A,Moffman DM,Nanna M,et al.Transesophageal echocardiography for the evaluation of mitral valve prostheses in the weanling sheep. ASAIO Transactions American Society for Artificial Internal Organs . 1991
  • 6Chen RuKun,Ji RongMing.The mitral valve apparatus in sheep. Chinese Journal of Cardiology . 1992
  • 7Ihlen H,Molstad P,Simonsen S,et al.Hemodynamic evaluation of the CarboMedics prosthetic heart valve in the aortic position: Comparion of noninvasive and invasive techniques. American Heart Journal . 1992