期刊文献+

Chinese-made electrolytic detachable coil in the embolization of a dog aneurysmal model 被引量:2

Chinese-made electrolytic detachable coil in the embolization of a dog aneurysmal model
原文传递
导出
摘要 Obejctive To develop a Chinese-made electrolytic detachable coil (CEDC) that would allow patients to enjoy the benefit of electrolytic detachable coil without having to rely on the expensive Guglielmi detachable coil (GDC), and to test the safety and efficiency of CEDC Methods Radiopacity of the marker of the CEDC was tested The anti strain force of coils and connection points were measured In vitro and in vivo electrolyses were conducted We produced 21 aneurysm models including lateral, bifurcation, and terminal aneurysm models, and embolized 18 models with CEDC Results Radiopacity of the marker was satisfactory Anti strain of the coil and the connection point have shown the safety and efficiency of CEDC Electrolysis in vitro and vivo, was similar to that of GDC 83% of the aneurysm models were completely occluded Coils were found to induce thrombosis in the aneurysm cavity, and could lead to a new endothelium over the entrance of the aneurysm, with organized tissue replacing thrombosis in 2 months Conclusions CEDC is as efficient and safe as GDC The marker, the ability to induce thrombosis inside the sac and the growth of new endothelium over the orifice are very satisfactory Obejctive To develop a Chinese-made electrolytic detachable coil (CEDC) that would allow patients to enjoy the benefit of electrolytic detachable coil without having to rely on the expensive Guglielmi detachable coil (GDC), and to test the safety and efficiency of CEDC Methods Radiopacity of the marker of the CEDC was tested The anti strain force of coils and connection points were measured In vitro and in vivo electrolyses were conducted We produced 21 aneurysm models including lateral, bifurcation, and terminal aneurysm models, and embolized 18 models with CEDC Results Radiopacity of the marker was satisfactory Anti strain of the coil and the connection point have shown the safety and efficiency of CEDC Electrolysis in vitro and vivo, was similar to that of GDC 83% of the aneurysm models were completely occluded Coils were found to induce thrombosis in the aneurysm cavity, and could lead to a new endothelium over the entrance of the aneurysm, with organized tissue replacing thrombosis in 2 months Conclusions CEDC is as efficient and safe as GDC The marker, the ability to induce thrombosis inside the sac and the growth of new endothelium over the orifice are very satisfactory
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2000年第10期57-62,共6页 中华医学杂志(英文版)
基金 TheresearchwassupportedbytheNationalProgramforKeyScienceandTechnologyProject the 9thFive YearPlan (No .96 90 7 0 2 0 2 )
关键词 ANEURYSMS electrolytic detachable coils aneurysms · electrolytic detachable coils
  • 相关文献

参考文献14

  • 1Spetzger U,Reul J,Weis J,et al.Microsurgically produced bifurcation aneurysms in a rabbit model for endovascular coil embolization. Journal of Neurosurgery . 1996
  • 2Reul J,Weis J,Spetzger U,et al.Long-term angiographic and histopathologic findings in experimental aneurysms of the carotid bifurcation embolized with platinum and tungsten coils. American Journal of Neuroradiology . 1997
  • 3Weill A,Ducros V,Cognard C,et al.Corrosion of tungsten spirals.A disturbing finding. Interventional Neuroradiology . 1998
  • 4Vinuela F,Duckwiler G,Mawad M,et al.Guglielmi detachable coil embolization of acute intracranial aneurysm:perioperative anatomical and clinical outcome in 403 patients. Journal of Neurosurgery . 1997
  • 5Macdonald RL,Mojtahedi S,Johns L,et al.Randomized comparison of Guglielmi detachable coils and cellulose acetate polymer for treatment of aneurysms in dogs. Stroke . 1998
  • 6Malisch TW,Gugliemi G,Vinuela F,et al.Intracranial aneurysms treated with the Guglielmi detachable coil: midterm clinical results in a consecutive of 100 patients. Journal of Neurosurgery . 1997
  • 7Wu ZX,Wang CC,Zhang YP,et al.Intravascular embolization of intracranial aneurysms of posterior-circulation with micro-coils. Chinese Journal of Radiology . 1996
  • 8Boccardi E,Branca V,Valvassori L,et al.Endovascular treatment with GDC: results in 100 patients. Journal of Neurosurgical Sciences . 1998
  • 9Tenjin H,Fushiki S,Nakahara Y,et al.Effect of Guglielmi detachable coils on experimental carotid artery aneurysms in primates. Stroke . 1995
  • 10Guglielmi G,Sepetka I.Endovascular electrolytically detachable wire and tip for the formation of thrombus in arteries, veins,aneurysms, vascular malformations and arteriovenous fistulas. . 1999

同被引文献4