期刊文献+

(99)~m Tc -MIBI and(99)~Tc-MDP scintimammography for detecting breast carcinoma

(99)~m Tc-MIBI and (99)~m Tc-MDP scintimammography for detecting breast carcinoma
原文传递
导出
摘要 To assess the value of scintimammography with both 99m TC-MIBI and 99m Tc-MDP in detecting breast cancer. Methods A total of 35 women with clinical findings of suspicious breast lesions were studied with both 99m Tc MIBI and 99m Tc-MDP scintimammography. All patients underwent surgery within one week and the finaldiagnostic results (histopathological) were obtained. Results Eighteen of 35 abnormalities of breast were pathologically confirmed as breast cancer and 17 as benign lesions. In this group of patients studied, the sensitivity, specificity and accuracy of 99m Tc-MIBI scintimammography were 77. 8%, 88.2% and 82.9%, respectively and those of 99m TC-MDP scintimammography were 72.2%, 88.2% and 80.0%, respectively. There was no significant difference between 99m TC-MIBI and 99m Tc-MDP scintimammography.Conclusion This study showed the high diagnostic accuracy of both 99m TC-MIBI and 99m TC-MDP scintimammography in detecting breast cancer. Both can be used as non-invasively assess breast cancer invasiveness before surgery. To assess the value of scintimammography with both 99m TC-MIBI and 99m Tc-MDP in detecting breast cancer. Methods A total of 35 women with clinical findings of suspicious breast lesions were studied with both 99m Tc MIBI and 99m Tc-MDP scintimammography. All patients underwent surgery within one week and the finaldiagnostic results (histopathological) were obtained. Results Eighteen of 35 abnormalities of breast were pathologically confirmed as breast cancer and 17 as benign lesions. In this group of patients studied, the sensitivity, specificity and accuracy of 99m Tc-MIBI scintimammography were 77. 8%, 88.2% and 82.9%, respectively and those of 99m TC-MDP scintimammography were 72.2%, 88.2% and 80.0%, respectively. There was no significant difference between 99m TC-MIBI and 99m Tc-MDP scintimammography.Conclusion This study showed the high diagnostic accuracy of both 99m TC-MIBI and 99m TC-MDP scintimammography in detecting breast cancer. Both can be used as non-invasively assess breast cancer invasiveness before surgery.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2000年第5期16-19,共4页 中华医学杂志(英文版)
关键词 breast cancer scintimammography 99m Tc-MIBI. 99m TC-MDP breast cancer scintimammography 99m Tc-MIBI. 99m Tc-MDP
  • 相关文献

参考文献4

  • 1F. Scopinaro,O. Schillaci,M. Scarpini,P. L. Mingazzini,L. Macio,M. Banci,R. Danieli,M. Zerilli,M. R. Limiti,A. Centi Colella. Technetium-99m sestamibi: an indicator of breast cancer invasiveness[J] 1994,European Journal of Nuclear Medicine(9):984~987
  • 2C.H. Kao,S.J. Wang,T.J. Liu. The use of technetium-99m methoxyisobutylisonitrile breast scintigraphy to evaluate palpable breast masses[J] 1994,European Journal of Nuclear Medicine(5):432~436
  • 3Iraj Khalkhali,Ismael Mena,Linda Diggles. Review of imaging techniques for the diagnosis of breast cancer: a new role of prone scintimammography using technetium-99m sestamibi[J] 1994,European Journal of Nuclear Medicine(4):357~362
  • 4Paul Crane,Robert Laliberté,Stuart Heminway,Martin Thoolen,Cesare Orlandi. Effect of mitochondrial viability and metabolism on technetium-99m-sestamibi myocardial retention[J] 1993,European Journal of Nuclear Medicine(1):20~25